Esse-ti HELPY 2W-4G.VoLTE 24 Vdc Quick Manual

Esse-ti HELPY 2W-4G.VoLTE 24 Vdc Quick Manual

Alarm system for elevators compliant with the european standard en 81-28:2018

Advertisement

Quick Links

Alarm system for elevators
compliant with the European Standard
EN 81-28:2018
HELPY 2W-4G.VoLTE
24 Vdc
QUICK GUIDE
14/03/2027

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HELPY 2W-4G.VoLTE 24 Vdc and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Esse-ti HELPY 2W-4G.VoLTE 24 Vdc

  • Page 1 Alarm system for elevators compliant with the European Standard EN 81-28:2018 HELPY 2W-4G.VoLTE 24 Vdc QUICK GUIDE 14/03/2027...
  • Page 2 DESCRIPTION Not present Not present Female DB-9 connector Termination jumpers (J12: CAN-bus / J13: RS-485) Antenna cable connector Reset pushbutton Alarm pushbutton LEDs SIM card slot Serial port for PC connection Micro SD card slot Micro USB A/B port Not present Terminal blocks Page 2 DESCRIPTION...
  • Page 3 LEDs Alarm / periodical test call (yellow) Device status (red) Mobile network signal strength (green) Power supply status (blue) ATTENTION Check with your network provider that VoLTE service is active on the SIM card you are using. DESCRIPTION Page 3...
  • Page 4: Terminal Blocks

    Terminal blocks 24 Vdc power supply input — Negative pole BUS+ Bus for connecting 2W speaker units Bus for connecting 2W speaker units Bus for connecting 2W speaker units BUS+ Bus for connecting 2W speaker units TEL+ Local telephone TEL- Local telephone Input 1 (freely programmable;...
  • Page 5: Connecting The Telephone Line

    CONNECTING THE TELEPHONE LINE Inserting the SIM card Before inserting the SIM card, make sure the device is off and use all due precaution to avoid electrostatic discharge. ➢ Remove the cover. ➢ Push the SIM Card housing cover as indicated by the arrow OPEN until it unlocks and lift it.
  • Page 6 CONNECTING THE SPEAKER UNITS It is possible to connect to the Helpy 2W-4G.VoLTE up to 16 independent 2W speaker units by means of the 2-wire bus. The bus can power 4 speaker units, the remaining 12 must be powered by the specific +12 input.
  • Page 7 2W speaker unit description Loudspeaker Given alarm indicator light * Received alarm indicator light * DIP switch for ID assignation Pushbutton * Terminal blocks: Power supply input 12 Vdc — Negative Received alarm indicator light (light positive pole) Given alarm indicator light (light positive pole) AR—...
  • Page 8 Terminal blocks for connecting a passive speaker unit ALT2 Output for connecting the loudspeaker of a passive speaker unit MIC2 Input for connecting the microphone of a passive speaker unit or a single microphone — Negative Microphone DIP switch The DIP switch allows to assign an ID (01~16) to each 2W speaker unit connected to the bus.
  • Page 9 CONNECTING THE EMERGENCY CALL BUTTONS It is possible to connect external pushbuttons (voltage free contact pushbuttons or powered pushbuttons) to 2W speaker units. ➢ Connect, following one of the diagrams shown below, the external pushbutton to the 2W speaker unit. CONNECTING THE EMERGENCY CALL BUTTONS Page 9...
  • Page 10 CONNECTING THE INDICATOR LIGHTS The GIVEN ALARM INDICATOR LIGHT (yellow) switches on after pressing the emergency button to indicate the beginning of the alarm procedure. The RECEIVED ALARM INDICATOR LIGHT (green) switches on when the alarm call is answered. Some 2W speaker unit models come with built-in indicator lights. It is also possible to connect external indicator lights.
  • Page 11: Other Connections

    OTHER CONNECTIONS ONNECTING THE LOCAL TELEPHONE ➢ Connect the local telephone for programming and managing the device to TEL terminals (irrespective of the polarity). ONNECTING THE FILTER INPUT ➢ Connect the filter contact as per one of the modes shown in the table: C3-4 TERMINAL FILTER CONTACT CONNECTED TO:...
  • Page 12: Wiring Diagrams

    WIRING DIAGRAMS IRING DIAGRAM WITH SPEAKER UNIT IN THE PIT AND PASSIVE SPEAKER UNIT ON CAR TOP Page 12 WIRING DIAGRAMS...
  • Page 13 IRING DIAGRAM WITH LANDING FLOORS WIRING DIAGRAMS Page 13...
  • Page 14 MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION 1. PROGRAMMING ➢ Access to programming: lift the local telephone handset and dial The programming activated message will be heard. ➢ Program a telephone number for the emergency-call alarm: dial <telephone number> ➢ Record the identification message of the specific elevator, which is meant to contain all necessary information concerning the elevator location: dial and, after the “Correct”...
  • Page 15 ➢ Answer by the called party. The voice messages will be heard. ➢ Press to speak with the trapped person. mode: immediate and automatic two-way communication (no messages) ➢ Answer by the called party. ➢ Speak with the trapped person. 4.
  • Page 16: Using The Reset Button

    SING THE RESET BUTTON Note: the reset operation does not alter the previously set parameters. Use of the reset pushbutton (F in the picture at page 2): Pressing shortly Allows to interrupt an alarm call. By pressing shortly, you get the same result as lifting the handset of the local telephone and entering * <Password>...
  • Page 17: Basic Programming

    < INSTALLER or OPERATOR PASSWORD > PROGRAMMING (factory default: SOURCE RECEIVER emergency- — call button — USER periodic automatic test ESSE-TI call * … 2W speaker (X..X = unit connection telephone failure alarm * number, (position TELEPHONE max. 20 from 01 to...
  • Page 18 23 alarm start notification * 24 timer 26 emergency-call button - night time slot (set programming code 90032) receiver: * the programming 2 user of the telephone 3 Esse-ti protocol number 4 CLI automatically 5 SMS activates the 6 P100 protocol alarm/call...
  • Page 19 BASIC PROGRAMMING WEEKDAY SUNDAY MONDAY TUESDAY DATE (INST) (dd) (mm) (yy) WEDNESDAY THURSDAY FRIDAY SATURDAY TIME (hhmm, from 0000 to 2359) (INST) NIGHT TIME SLOT (hhmm, from 0000 (hhmm, from 0000 to 2359, (INST) to 2359, start) end) identification message RECORD (max.
  • Page 20 DATA Automatic (INST) automatic test enabled (EN 81-28:2018) test alarm automatic test enabled (EN 81-28:2004) Make a test call manually PROTOCOLS Esse-ti IDENTIFICATION … (identification code) CODE P100 (INST) P100 PROTOCOL IDENTIFICATION CODE FOR speaker unit ID …...
  • Page 21: Advanced Programming

    Advanced programming ADVANCED PROGRAMMING CHANGE THE INSTALLER … PASSWORD “0” (old) (new) (new) (INST) CHANGE THE OPERATOR … PASSWORD “1” (old) (new) (new) (INST) INPUTS input NORMALLY type (1=IN1 OPEN/CLOSED (0=normally closed 2=IN2 (INST) 1=normally open) 3=IN3 4=IN4) IN1=alarm / IN2=reset / IN3=bist. / IN4=bist. IN1=filter / IN2=reset / IN3=bist.
  • Page 22 ADVANCED PROGRAMMING … seconds INPUTS input (from 0 to 9999) ACTIVATION (1=IN1 (factory default: TIME 2=IN2 - if alarm/auxiliary input:3 s (INST) 3=IN3 - if reset/filter/gong/counter input: 4=IN4) 100 ms - if bistable input: 20 s) … input minutes TIMER (1=IN1 (from 1 to (INST)
  • Page 23 ADVANCED PROGRAMMING 3= Esse-ti 4= CLI 5= SMS 6= P100 - if receiver 3, set the Esse-ti protocol ID: 222 YYYYYYYYYY - if receiver 6, set the P100 protocol ID: 223 ZZZZZZZZ# EXAMPLE OF - if receiver 6, you can customize the P100 protocol codes using the e-...
  • Page 24 ADVANCED PROGRAMMING INSUFFICIENT BUTTON disabled message PRESSURE MESSAGE SETTING enabled message (INST) BEEP ENABLING WHEN 2W beep disabled SPEAKER UNIT PUSHBUTTON IS PRESSED beep enabled (INST) 2W SPEAKER speaker (0=alarm NC UNIT INPUTS (0=normally closed unit ID 1=alarm NO SETTING 1=normally (from 01 2=auxiliary NC...
  • Page 25 ADVANCED PROGRAMMING REPEATS OF COURTESY (seconds between two courtesy messages, from MESSAGE 02 to 59; 00=no courtesy message; 01=one DURING AN courtesy message for each call) ALARM (INST) CALL DELAY AFTER COURTESY (seconds of waiting after the courtesy message MESSAGE before sending the call, from 0 to 9) (INST) PLAYBACK OF...
  • Page 26 ADVANCED PROGRAMMING RESTORE identification message FACTORY MESSAGES courtesy message (INST) LANGUAGE (INST) (language: 00 Italian, 01 English, 02 German, (available 03 French, 04 Polish, 05 Portuguese, languages may 06 Russian, 07 Spanish, 09 Czech, 10 Croatian, vary depending on 11 Greek, 13 Slovenian, 19 Chinese, model or country of 21 Flemish, 23 Swedish, 26 Slovak) installation)
  • Page 27 ADVANCED PROGRAMMING DURATION OF CALL TO EACH (seconds, from 15 to 60) NUMBER (INST) CLI CALL DURATION (seconds, from 00 to 99; factory default 10) (CLI) AUTOMATIC (ring number, from 1 to 9; ANSWER 0=disabled; factory default 2) (INST) OPERATION programming mode MODE AFTER AUTOMATIC...
  • Page 28 ADVANCED PROGRAMMING ENABLE ROAMING (INST) ENTER SIM CARD PIN CODE … (PIN) … (PIN) (INST) DISABLE SIM CARD PIN … (PIN) REQUEST (INST) GSM /UMTS COMMUNICA- UMTS TION TECHNOLOGY SETTING (INST) UMTS / LTE GSM / LTE GSM / UMTS / LTE LISTEN TO THE Digits Quality...
  • Page 29 ADVANCED PROGRAMMING VOLUME OF VOLTE DTMF (volume, from 0 to 9; 5 factory default; TONES OUT OF do not change unless it is strictly necessary) BAND (INST) APN SETTING APN[,user,pwd] (INST) communication disabled SERIAL COMMUNICATION RS-232 STANDARD SETTING RS-485 (INST) CAN-bus bits per second data bits...
  • Page 30 ADVANCED PROGRAMMING REGISTRATION deleting TO SERVER COMNET (INST) registering E-STANT WEB notification to e-stant web disabled DATA NOTIFICATION SETTING notification to e-stant web enabled (INST) INCREASING THE VOLUME OF THE IDENTIFICATION (value, from 0 to 5) MESSAGE (INST) emergency-call button periodic automatic test call 2W speaker unit connection failure alarm TEST OF ALARMS...
  • Page 31 - set a micro SD card to use for programming, customizing the messages and updating the firmware of the Helpy 2W-4G.VoLTE. e-stant can be downloaded at the following link: https://www.esse-ti.it/software/e-stant/ Remote programming via e-stant web It is possible to remotely program Helpy 2W-4G.VoLTE via e-stant web application: https://e-stant.esse-ti.it/...
  • Page 32: Programming Via Sms

    Programming via SMS All parameters programmable locally by the local telephone may also be set via SMS. Programming via SMS is possible by any mobile phone or other device supporting SMS. An SMS notifying the programming was performed is sent by the Helpy 2W- 4G.VoLTE to the number that sent the programming.
  • Page 33: Local Use

    Local use : lift the local telephone handset : lift the local telephone handset and dial to access programming LOCAL USE CABIN SPEAKER UNIT (ID 01) CABIN SPEAKER UNIT (ID 01) CONVERSATION WITH THE SPEAKER UNIT (ID 02) SPEAKER UNITS SPEAKER UNIT (ID 03) SPEAKER UNIT ID XX (04~16) PROGRAMMING...
  • Page 34 ➢ Dial <password> (factory default: ) to access programming. ➢ All of the programming and functions below can now be performed: USE REMOTELY WITH HELPY 2W-4G.VoLTE AT REST PROGRAMMING … CABIN SPEAKER UNIT (ID 01 SPEAKER UNIT (ID 02) CONVERSATION WITH THE SPEAKER UNIT (ID 03) SPEAKER UNITS SPEAKER UNIT ID XX (04~16)
  • Page 35 SIGNALS AND NOTES LED signalling alarm / periodical test call (yellow) Emergency-call alarm Emergency call alarm suspended Other alarms - Test call LED signalling mobile network signal strength (green) No signal Low signal level (2G/3G/4G network – VoLTE not available; connection not guaranteed) Medium signal level (2G/3G/4G network –...
  • Page 36 Low signal level (4G network – VoLTE available) Medium signal level (4G network – VoLTE available) Good signal level (4G network – VoLTE available) High signal level (4G network – VoLTE available) LED signalling device status (red) Normal operation (no alarm) Alarm Voice connection 2W speaker unit connection error or bus problem...
  • Page 37 LED signalling power supply status (blue) External power supply connected Given alarm indicator light (yellow) Alarm Received alarm indicator light (green) Voice connection Missed test call notification (EN 81-28:2018) The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call.
  • Page 38: Eu Declaration Of Conformity

    EU declaration of conformity Hereby, Esse-ti S.r.l. declares that the radio equipment type Helpy 2W- 4G.VoLTE is in compliance with Directives 2014/33/EU and 2014/53/EU. The full text of the EU declaration of conformity is available from the following Internet address: https://www.esse-ti.it/en/eu-declaration-of-conformity...
  • Page 39 SIGNALS AND NOTES Page 39...
  • Page 40 Esse-ti S.r.l. Via G. Capodaglio, 9 62019 Recanati (MC) – ITALY Tel. +39 071 7506066 www.esse-ti.it support@esse-ti.it...

Table of Contents