Alarm system for elevators compliant with the european standard en 81-28:2018 (37 pages)
Summary of Contents for Esse-ti HELPY COMPACT
Page 1
Alarm system for elevators compliant with the European Standard EN 81-28:2018 HELPY COMPACT QUICK GUIDE To download User guides in other languages please scan the QR-code or visit https://www.esse-ti.it/en/manuals 7IS-80465 19/02/2021...
Page 2
E Built-in microphone F Device status LED ( ) G Reset pushbutton H Serial port for PC connection Alarm pushbutton L Micro SD Card slot M Fixing holes Helpy Compact models CODE / NAME BUILT-IN LEDS BUILT-IN BATTERY 5HL-600 • •...
TERMINAL BLOCKS PSTN-line or universal gateway input PSTN-line or universal gateway input Ground terminal for PSTN-line Output for domestic telephone line Output for domestic telephone line Local telephone — Negative RL1 NO Relay (normally open contact) RL1 NC Relay (normally closed contact) RL1 C Relay (common contact) Power supply input (10 Vdc - 30 Vdc)
Page 4
— Negative Alarm input : can be connected to a block –, to the block +12 or to an external reference : allows to connect voltage free contact pushbuttons (NO or NC) or powered pushbuttons : allows to connect voltage free contact (NO or NC) Page 4 TERMINAL BLOCKS...
INSTALLATION Helpy Compact can be fixed with 2 screws or with the pre-drilled double-sided adhesive rubber supplied. Fixing with double-sided adhesive rubber Remove the film from one side of the adhesive rubber. Attach the adhesive rubber to the COP, paying attention that the hole reserved for the microphone of the Helpy Compact (E in the picture at page 2) corresponds to a free hole of the COP.
Page 6
CONNECTING THE SPEAKER UNITS Helpy Compact comes with a built-in speaker unit. It is also possible to connect to the Helpy Compact up to 2 passive speaker units or cables with microphone and up to 2 long range speaker units.
Page 7
CONNECTING THE EMERGENCY CALL BUTTONS Connect, following one of the diagrams shown below, the pushbuttons. Car pushbutton It is possible to connect (inside the elevator car) voltage free contact pushbuttons or powered pushbuttons. Voltage free contact pushbuttons Powered pushbuttons (12-24 Vdc) – 2 solutions CONNECTING THE EMERGENCY CALL BUTTONS Page 7...
Page 8
Other pushbuttons The pushbuttons of pit, top and bottom of elevator car can only be connected to an AL1 terminal block if they are of the same type as the car pushbutton (voltage free or powered, normally open or normally closed). The pushbuttons of pit, top and bottom of elevator car can only be connected to AL2 terminal block if they are voltage-free.
Page 9
CONNECTING THE FILTER INPUT Connect, following one of the diagrams shown below, the filter contact. CONNECTING THE FILTER INPUT Page 9...
Page 10
RECEIVED ALARM INDICATOR LIGHT (green) switches on when communication is established. Some Helpy Compact models come with built-in indicator lights. It is also possible to connect external indicator lights. Connect, following one of the diagrams shown below, the external indicator lights to the Helpy Compact.
OTHER CONNECTIONS ONNECTING THE TELEPHONE LINE PSTN line or universal gateway (2G/3G/4G) Connect the telephone line to LTI terminals. Connect the ground terminal (indicated by ), to a ground socket in order to increase the PSTN line protection. ONNECTING THE LOCAL TELEPHONE ...
Page 12
Example of wiring diagram with speaker unit in the pit Page 12 OTHER CONNECTIONS...
Page 13
Example of wiring diagram with speaker unit in the elevator car bottom OTHER CONNECTIONS Page 13...
URNING ON Connect the external (10 Vdc - 30 Vdc) power supply to + and — terminals. Helpy Compact lights up and the device status LED starts flashing. URNING OFF 5HL-600 / 5HL-603 Disconnect the external (10 Vdc - 30 Vdc) power supply from + and —...
Page 15
MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION 1. PROGRAMMING Access to programming: lift the local telephone handset and dial The programming activated message will be heard. Program a telephone number for the emergency-call alarm: dial <telephone number> Record the identification message of the specific elevator, which is meant to contain all necessary information concerning the elevator location: dial and, after the “Correct”...
mode: two-way communication established after input of “Communication activation” code Answer by the called party. The voice messages will be heard. Press to speak with the trapped person. mode: immediate and automatic two-way communication (no messages) Answer by the called party. ...
Page 17
* <Password> #. Pressing longer (10 seconds) Allows to reset the device. By pressing longer, the Helpy Compact will be re-started with no need to disconnect the power supply. Note: it is also possible to reset the device through the code 995*0#.
BASIC PROGRAMMING DELETE A TELEPHONE (position from 01 to NUMBER (INST) WEEKDAY SUNDAY MONDAY TUESDAY DATE * (dd) (mm) (yy) (INST) WEDNESDAY THURSDAY * to be FRIDAY reprogrammed in SATURDAY case of turn off TIME * (hhmm from 0000 to 2359) (INST) identification message...
Page 20
AUTOMATIC TEST automatic test disabled DATA Automatic (INST) automatic test enabled (EN 81-28:2018) test alarm automatic test enabled (EN 81-28:2004) Make a test call manually PROTOCOLS Esse-ti IDENTIFICATION … (identification code) CODE P100 (INST) SPEAKER UNITS loudspeaker microphone VOLUME (from 1 to...
(INST) 3= Esse-ti 4= CLI 6= P100 - if receiver 3, set the Esse-ti protocol ID: 222 YYYYYYYYYY - if receiver 6, set the P100 protocol ID: 223 ZZZZZZZZ# - if receiver 6, customize the P100 protocol codes using the e-stant software (programming code 203) Note: AL2 and IN1 are automatically configured as normally closed;...
ADVANCED PROGRAMMING NO EXTERNAL POWER SUPPLY disabled alarm ALARM * (INST) enabled alarm with XX minutes delay * 5HL-600 / 5HL-603 (from 01 to 99) only THRESHOLD OF THE NO … (mV on the + and - terminals, EXTERNAL from 1 to 5 digits; factory default POWER SUPPLY 9000) ALARM...
Page 24
ADVANCED PROGRAMMING two-way communication established after input of "Communication activation" code TWO-WAY COMMUNICATIO automatic two-way communication N MODE DURING established after messages AN ALARM (INST) immediate and automatic two-way communication (no messages) automatic reset ALARM RESET MODE alarm reset by “End alarm” code (INST) automatic reset with local acknowledgement “PLAY...
Page 25
ADVANCED PROGRAMMING DURATION OF TWO-WAY COMMUNICA- (minutes, from 2 to 9) TION DURING AN ALARM (INST) NUMBER OF CALLS TO THE SAME NUMBER (calls, from 1 to 9) FOR EACH CYCLE (INST) CALL CYCLES FOR EMERGENCY CALL (cycles, from 1 to 9; 0=unlimited) ALARMS (INST) CALL CYCLES FOR...
ADVANCED PROGRAMMING CONNECTION DURATION AFTER AUTOMATIC (minutes, from 1 to 9) RESPONSE (INST) DTMF (from 1 to 9; factory default 2; GENERATOR DTMF duration=X*50 ms) (INST) MULTI-LINK FUNCTION (from 0 to 9; 1=master, 0=function disabled) (INST) RELAY steady-state INTERMITTENCE (INST) intermittent (500 ms ON / 500 ms OFF) same behaviour as outputs AI same behaviour as outputs AR...
Local programming via e-stant software It is possible to program Helpy Compact via computer by using the USB/serial proprietary cable and the dedicated e-stant software. e-stant software also allows to: - update the firmware of the Helpy Compact...
EXTERNAL CALLS <TELEPHONE NUMBER> DOOR OPENER RELAY Use remotely with Helpy Compact at rest Call Helpy Compact and wait for a response. Listen to the elevator identification message, if present. Dial to speak with all speaker units.
SIGNALS Device status LED ( ) Normal operation (no alarm) Alarm Voice connection Battery disconnected or low battery (max. 1-hour operation in idle state) Absence of telephone line Button failure SIGNALS Page 29...
Page 30
Given alarm indicator light (yellow) Alarm Received alarm indicator light (green) Voice connection Missed test call notification (EN 81-28:2018) The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call. The flashing sequence ends after the next successful test call or emergency call.
Page 31
ATTENTION Only use replacement batteries supplied by Esse-ti. Remove the screw located on the back side of Helpy Compact. Release the cover by acting on the wings at the top or bottom. Turn the cover to the right paying attention to the loudspeaker connection cable.
Need help?
Do you have a question about the HELPY COMPACT and is the answer not in the manual?
Questions and answers