Alarm system for elevators compliant with the European Standard EN 81-28:2018 HELPY 2W-xG QUICK GUIDE 13/01/2020...
Page 2
DESCRIPTION Built-in backup battery connector Internal power-supply connector Female DB-9 connector * Termination jumper * Antenna cable connector Reset pushbutton Alarm pushbutton LEDs SIM card slot with front panel Serial port for PC connection Micro SD card slot Micro USB A/B port Terminal blocks only for Net models Page 2...
Page 3
Helpy 2W-xG models CODE MODEL 5HL-500 Helpy 2W-2G Voice 5HL-510 Helpy 2W-2G Net 5HL-520 Helpy 2W-4G Voice 5HL-530 Helpy 2W-4G Net LEDs Alarm / periodical test call (yellow) Device status (red) Mobile network signal strength (green) Power supply status (blue) DESCRIPTION Page 3...
Terminal blocks 12 Vdc power supply input — Negative pole BUS+ Bus for connecting 2W speaker units Bus for connecting 2W speaker units Bus for connecting 2W speaker units BUS+ Bus for connecting 2W speaker units TEL+ Local telephone TEL- Local telephone Input 1 (freely programmable;...
CONNECTING THE TELEPHONE LINE Inserting the SIM card Before inserting the SIM card, make sure the device is off and use all due precaution to avoid electrostatic discharge. Remove the cover. Push the SIM Card housing cover as indicated by the arrow OPEN until it unlocks and lift it.
Page 6
CONNECTING THE SPEAKER UNITS It is possible to connect to the Helpy 2W-xG up to 16 independent 2W speaker units by means of the 2-wire bus. The bus can power 4 speaker units, the remaining 12 must be powered by the specific +12 input.
Page 7
2W speaker unit description Loudspeaker Given alarm indicator light * Received alarm indicator light * DIP switch for ID assignation Pushbutton * Terminal blocks: Power supply input 12 Vdc — Negative Received alarm indicator light (light positive pole) Given alarm indicator light (light positive pole) AR—...
Page 8
Terminal blocks for connecting a passive speaker unit ALT2 Output for connecting the loudspeaker of a passive speaker unit MIC2 Input for connecting the microphone of a passive speaker unit or a single microphone — Negative Microphone DIP switch The DIP switch allows to assign an ID (01~16) to each 2W speaker unit connected to the bus.
Page 9
CONNECTING THE EMERGENCY CALL BUTTONS It is possible to connect external pushbuttons (voltage free contact pushbuttons or powered pushbuttons) to 2W speaker units. Connect, following one of the diagrams shown below, the external pushbutton to the 2W speaker unit. CONNECTING THE EMERGENCY CALL BUTTONS Page 9...
Page 10
CONNECTING THE INDICATOR LIGHTS The GIVEN ALARM INDICATOR LIGHT (yellow) switches on after pressing the emergency button to indicate the beginning of the alarm procedure. The RECEIVED ALARM INDICATOR LIGHT (green) switches on when the alarm call is answered. Some 2W speaker unit models come with built-in indicator lights. It is also possible to connect external indicator lights.
OTHER CONNECTIONS ONNECTING THE LOCAL TELEPHONE Connect the local telephone for programming and managing the device to TEL terminals (irrespective of the polarity). ONNECTING THE FILTER INPUT Connect the filter contact as per one of the modes shown in the table: C3-4 TERMINAL FILTER CONTACT CONNECTED TO:...
Page 14
MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION 1. PROGRAMMING Access to programming: lift the local telephone handset and dial The programming activated message will be heard. Program a telephone number for the emergency-call alarm: dial <telephone number> Record the identification message of the specific elevator, which is meant to contain all necessary information concerning the elevator location: dial and, after the “Correct”...
Page 15
Answer by the called party. The voice messages will be heard. Press to speak with the trapped person. mode: immediate and automatic two-way communication (no messages) Answer by the called party. Speak with the trapped person. 4.
Page 16
By pressing longer, the Helpy 2W-xG will be re-started with no need to disconnect the power supply. Note: it is also possible to reset the device through the code 995*0#. ATTERY REPLACEMENT ATTENTION Only use replacement batteries supplied by Esse-ti. Page 16 MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION...
EXITING THE PROGRAMMING (factory default: SOURCE RECEIVER emergency- — call button battery USER alarms * periodic automatic test ESSE-TI call * … 2W speaker (X..X = unit connection telephone failure alarm number, (position max. 20 TELEPHONE from 01 to SIM card digits;...
Page 18
BASIC PROGRAMMING DELETE A TELEPHONE (position from NUMBER 01 to 24) (INST) WEEKDAY SUNDAY MONDAY TUESDAY DATE (INST) (dd) (mm) (yy) WEDNESDAY THURSDAY FRIDAY SATURDAY TIME (hhmm, from 0000 to 2359) (INST) identification message RECORD (max. 25s ) MESSAGES (record) (hang up) (INST) courtesy message...
Page 19
AUTOMATIC TEST automatic test disabled DATA Automatic (INST) automatic test enabled (EN 81-28:2018) test alarm automatic test enabled (EN 81-28:2004) Make a test call manually PROTOCOLS Esse-ti IDENTIFICATION … (identification code) CODE P100 (INST) SPEAKER UNITS loudspeaker microphone VOLUME speaker unit ID...
Page 21
ADVANCED PROGRAMMING 2W SPEAKER speaker (0=alarm NC UNIT INPUTS unit ID 1=alarm NO (0=normally closed SETTING (from 01 2=auxiliary NC 1=normally open) (INST) to 16) 3=auxiliary NO 4=filter NC 5=filter NO NO EXTERNAL disabled alarm POWER SUPPLY ALARM enabled alarm with XX minutes delay (INST) (from 01 to 99) 2W SPEAKER...
Page 22
ADVANCED PROGRAMMING “COMMUNICA- TION disabled message ACTIVATED” MESSAGE SETTING enabled message (INST) two-way communication established after input of TWO-WAY "Communication activation" code COMMUNICATIO automatic two-way communication established MODE DURING after messages AN ALARM immediate and automatic two-way communication (INST) (no messages) automatic reset ALARM RESET MODE...
Page 23
ADVANCED PROGRAMMING DURATION OF TWO-WAY COMMUNICATIO (minutes, from 2 to 9) N DURING AN ALARM (INST) NUMBER OF CALLS TO THE SAME NUMBER (calls, from 1 to 9) FOR EACH CYCLE (INST) CALL CYCLES FOR EMERGENCY CALL (cycles, from 1 to 9; 0=unlimited) ALARMS (INST) CALL CYCLES FOR...
Page 24
ADVANCED PROGRAMMING same behaviour as outputs AI same behaviour as outputs AR active for external power failure door opener RELAY SETTING (INST) Relay active as long as the emergency alarm progresses active as long as the buttons are pressed active for telephone line failure active for low battery RELAY steady-state...
Page 25
ADVANCED PROGRAMMING DISABLE SIM CARD PIN REQUEST (INST) APN SETTING APN[,user,pwd] (INST) LISTEN TO THE BATTERY LEVEL (expressed in mV) (INST) LISTEN TO THE EXTERNAL POWER SUPPLY (expressed in mV) LEVEL (INST) emergency-call button battery alarm periodic automatic test call 2W speaker unit connection failure alarm TEST OF ALARMS (INST)
Page 26
- set a micro SD card to use for programming, customizing the messages and updating the firmware of the Helpy 2W-xG. e-stant can be downloaded at the following link: https://www.esse-ti.it/en/download/software-request Programming via micro SD card The micro SD card properly set allows to:...
Programming via SMS All parameters programmable locally by the local telephone may also be set via SMS. Programming via SMS is possible by any mobile phone or other device supporting SMS. An SMS notifying the programming was performed is sent by the Helpy 2W- xG to the number that sent the programming.
Local use : lift the local telephone handset : lift the local telephone handset and dial to access programming LOCAL USE CABIN SPEAKER UNIT (ID 01) CABIN SPEAKER UNIT (ID 01) CONVERSATION WITH THE SPEAKER UNIT (ID 02) SPEAKER UNITS SPEAKER UNIT (ID 03) SPEAKER UNIT ID XX (04~16) PROGRAMMING...
Page 29
Dial <password> (factory default: ) to access programming. All of the programming and functions below can now be performed: USE REMOTELY WITH HELPY 2W-xG AT REST PROGRAMMING … CABIN SPEAKER UNIT (ID 01 SPEAKER UNIT (ID 02) CONVERSATION WITH THE SPEAKER UNIT (ID 03) SPEAKER UNITS SPEAKER UNIT ID XX (04~16)
Page 30
SIGNALS LED signalling alarm / periodical test call (yellow) Emergency-call alarm Emergency call alarm suspended Other alarms - Test call LED signalling mobile network signal strength (green) No signal Low signal level (connection not guaranteed) Medium signal level Good signal level High signal level Page 30 SIGNALS...
Page 31
LED signalling device status (red) Normal operation (no alarm) Alarm Voice connection Battery disconnected or low battery (max. 1-hour operation in idle state) 2W speaker unit connection error or bus problem Absence of telephone line Button failure SIGNALS Page 31...
Page 32
LED signalling power supply status (blue) The external power supply is connected and the battery has max capacity charge The external power supply is connected and the battery has good capacity charge The external power supply is connected and the battery has medium capacity charge The external power supply is connected and the battery has low capacity charge...
Page 33
Given alarm indicator light (yellow) Alarm Received alarm indicator light (green) Voice connection Missed test call notification (EN 81-28:2018) The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call. The flashing sequence ends after the next successful test call or emergency call.
NOTE EU declaration of conformity Hereby, Esse-ti S.r.l. declares that the radio equipment type Helpy 2W-xG is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available from the following Internet address: https://www.esse-ti.it/en/eu-declaration-of-conformity Information to be provided with the lift The information (EN 81-28:2018 pt.