Esse-ti HELPY COMPACT-TL Quick Manual

For elevators compliant with the european standard

Advertisement

Quick Links

Alarm system for elevators
compliant with the European Standard
EN 81-28:2018
HELPY COMPACT-TL
QUICK GUIDE
To download User guides in other languages
please scan the QR-code or visit
https://www.esse-ti.it/en/manuals
11/06/2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HELPY COMPACT-TL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Esse-ti HELPY COMPACT-TL

  • Page 1 Alarm system for elevators compliant with the European Standard EN 81-28:2018 HELPY COMPACT-TL QUICK GUIDE To download User guides in other languages please scan the QR-code or visit https://www.esse-ti.it/en/manuals 11/06/2020...
  • Page 2 DESCRIPTION Autodialer specifically designed for installation on car roof. Internal power-supply connector Built-in backup battery connector Reset pushbutton Serial port for PC connection Alarm pushbutton Built-in loudspeaker connector Micro SD card slot Battery compartment Jumper J16 for define the behaviour of output AI Jumper J17 for define the behaviour of output AR Built-in microphone Terminal blocks...
  • Page 3: Terminal Blocks

    LEDs LED signalling alarm / periodical test call (yellow) (not used) LED signalling device status (red) LED signalling power supply status (blue) Terminal blocks Power supply input (12 Vdc - 30 Vdc) — Negative Given alarm indicator light (12 Vdc or 0 Vdc via jumper J16) Received alarm indicator light (12 Vdc or 0 Vdc via jumper J17) 12 Vdc output (max.
  • Page 4 Output for connecting loudspeaker of long range speaker unit (pit) Input for connecting microphone of long range speaker unit (pit) Input for connecting microphone of long range speaker unit (pit) — Negative Alarm input — Negative Alarm input : can be connected to a block –, to the block +12 or to an external reference : allows to connect voltage free contact pushbuttons (NO or NC) or powered pushbuttons : allows to connect voltage free contact (NO or NC) Page 4...
  • Page 5 CONNECTING THE SPEAKER UNITS Helpy Compact-TL comes with a built-in speaker unit. It is also possible to connect to the Helpy Compact-TL up to 2 passive speaker units or cables with microphone and up to 2 long range speaker units.
  • Page 6 CONNECTING THE EMERGENCY CALL BUTTONS  Connect, following one of the diagrams shown below, the pushbuttons. Car pushbutton It is possible to connect (inside the elevator car) voltage free contact pushbuttons or powered pushbuttons. Voltage free contact pushbuttons Powered pushbuttons (12-24 Vdc) – 2 solutions Page 6 CONNECTING THE EMERGENCY CALL BUTTONS...
  • Page 7 Other pushbuttons The pushbuttons of pit and bottom of elevator car can only be connected to an AL1 terminal block if they are of the same type as the car pushbutton (voltage free or powered, normally open or normally closed). The pushbuttons of pit and bottom of elevator car can only be connected to AL2 terminal block if they are voltage-free.
  • Page 8 CONNECTING THE FILTER INPUT  Connect, following one of the diagrams shown below, the filter contact. Page 8 CONNECTING THE FILTER INPUT...
  • Page 9 RECEIVED ALARM INDICATOR LIGHT (green) switches on when the alarm call is answered.  Connect, following one of the diagrams shown below, the external indicator lights to the Helpy Compact-TL. Output 12 Vdc (factory setting) Output 0 Vdc CONNECTING THE INDICATOR LIGHTS...
  • Page 10: Other Connections

     Connect the reset contact to AL2 and – terminals. ONNECTING THE RELAY  Connect the external contact to RL1 NO (or RL1 NC) and RL1 C terminals. EPLACING BATTERY ATTENTION Only use replacement batteries supplied by Esse-ti. Page 10 OTHER CONNECTIONS...
  • Page 11: Wiring Diagrams

    WIRING DIAGRAMS XAMPLE OF WIRING DIAGRAM WITH SPEAKER UNIT IN THE PIT WIRING DIAGRAMS Page 11...
  • Page 12 XAMPLE OF WIRING DIAGRAM WITH SPEAKER UNIT IN THE ELEVATOR CAR BOTTOM Page 12 WIRING DIAGRAMS...
  • Page 13 MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION 1. PROGRAMMING  Access to programming: lift the local telephone handset and dial The programming activated message will be heard.  Program a telephone number for the emergency-call alarm: dial <telephone number>  Record the identification message of the specific elevator, which is meant to contain all necessary information concerning the elevator location: dial and, after the “Correct”...
  • Page 14: Resetting The Alarm

    mode: two-way communication established after input of “Communication activation” code  Answer by the called party. The voice messages will be heard.  Press to speak with the trapped person. mode: immediate and automatic two-way communication (no messages)  Answer by the called party. ...
  • Page 15 * <Password> #. Pressing longer (10 seconds) Allows to reset the device. By pressing longer, the Helpy Compact-TL will be re-started with no need disconnect the power supply. Note: it is also possible to reset the device through the code 995*0#.
  • Page 16: Basic Programming

    < INSTALLER or OPERATOR PASSWORD > PROGRAMMING (factory default: SOURCE RECEIVER emergency- — call button battery USER alarms * periodic automatic test ESSE-TI call * … — (X..X = telephone TELEPHONE number, (position NUMBERS — — max. 20 from 01 to (INST) digits;...
  • Page 17 BASIC PROGRAMMING DELETE A TELEPHONE (position from 01 to NUMBER (INST) WEEKDAY SUNDAY MONDAY TUESDAY DATE * (dd) (mm) (yy) (INST) WEDNESDAY THURSDAY * to be FRIDAY reprogrammed in SATURDAY case of turn off TIME * (hhmm from 0000 to 2359) (INST) identification message...
  • Page 18 AUTOMATIC TEST automatic test disabled DATA Automatic (INST) automatic test enabled (EN 81-28:2018) test alarm automatic test enabled (EN 81-28:2004) Make a test call manually PROTOCOLS Esse-ti IDENTIFICATION … (identification code) CODE P100 (INST) SPEAKER UNITS loudspeaker microphone VOLUME (from 1 to...
  • Page 19: Advanced Programming

    Advanced programming ADVANCED PROGRAMMING CHANGE THE INSTALLER … PASSWORD “0” (old) (new) (new) (INST) CHANGE THE OPERATOR … PASSWORD “1” (old) (new) (new) (INST) INPUTS input NORMALLY type (1=AL1 OPEN/CLOSED (0=normally closed 2=AL2 (INST) 1=normally open) 3=IN1) AL2=alarm input / IN1=filter input AL2=auxiliary input / IN1=filter input AL2=alarm input / IN1=gong input AL2=auxiliary input / IN1=gong input...
  • Page 20: Input Configuration

    (INST) 3= Esse-ti 4= CLI 6= P100 - if receiver 3, set the Esse-ti protocol ID: 222 YYYYYYYYYY - if receiver 6, set the P100 protocol ID: 223 ZZZZZZZZZZ - if receiver 6, customize the P100 protocol codes using the e-stant software (programming code 203) Note: AL2 and IN1 are automatically configured as normally closed;...
  • Page 21 ADVANCED PROGRAMMING NO EXTERNAL disabled alarm POWER SUPPLY ALARM enabled alarm with XX minutes delay (INST) (from 01 to 99) BUILT-IN disabled alarm SPEAKER UNIT DIAGNOSTIC ALARM enabled alarm (INST) FILTER disabled ACTIVATION (INST/OPER) enabled FILTER BYPASS (seconds, from 15 to 30; 99=no bypass) (INST/OPER) ALARM AI indicator light lit and courtesy message...
  • Page 22 ADVANCED PROGRAMMING automatic reset ALARM RESET MODE alarm reset by “End alarm” code (INST) automatic reset with local acknowledgement “PLAY IDENTIFICATION (from 1 to 3 digits; factory default 5) … MESSAGE” CODE (INST) “COMMUNICA- TION ACTIVATION” … (from 1 to 3 digits; factory default 0) CODE (INST) “END ALARM”...
  • Page 23: Automatic Answer

    ADVANCED PROGRAMMING NUMBER OF CALLS TO THE SAME NUMBER (calls, from 1 to 9) FOR EACH CYCLE (INST) CALL CYCLES FOR EMERGENCY CALL (cycles, from 1 to 9; 0=unlimited) ALARMS (INST) CALL CYCLES FOR TECHNOLOGICAL (cycles, from 1 to 9; 0=10 cycles; ALARMS AND factory default 3) TEST CALLS...
  • Page 24 ADVANCED PROGRAMMING same behaviour as outputs AI same behaviour as outputs AR active for external power failure door opener RELAY SETTING (INST) active as long as the emergency alarm progresses active as long as the buttons are pressed active for telephone line absence active for low battery LISTEN TO THE BATTERY LEVEL...
  • Page 25 Programming via e-stant software It is possible to program Helpy Compact-TL via computer by using the USB/serial proprietary cable and the dedicated e-stant software. e-stant software also allows to: - update the firmware of the Helpy Compact-TL - customize the messages of the Helpy Compact-TL - set a micro SD card to use for programming, customizing the messages and updating the firmware of the Helpy Compact-TL.
  • Page 26: Local Use

    EXTERNAL CALLS <TELEPHONE NUMBER> DOOR OPENER RELAY Use remotely with Helpy Compact-TL at rest  Call Helpy Compact-TL and wait for a response.  Listen to the elevator identification message, if present.  Dial to speak with all speaker units.
  • Page 27: Device Status Led

    SIGNALS LED signalling alarm / periodical test call (yellow) Emergency-call alarm Emergency call alarm suspended Other alarms - Test call Device status LED (red) Normal operation (no alarm) Alarm Voice connection Battery disconnected or low battery (max. 1-hour operation in idle state) Absence of telephone line Button failure SIGNALS...
  • Page 28 LED signalling power supply status (blue) The external power supply is connected and the battery has max capacity charge The external power supply is connected and the battery has good capacity charge The external power supply is connected and the battery has medium capacity charge The external power supply is connected and the battery has low capacity charge...
  • Page 29 Given alarm indicator light (yellow) Alarm Received alarm indicator light (green) Voice connection Missed test call notification (EN 81-28:2018) The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call. The flashing sequence ends after the next successful test call or emergency call.
  • Page 30: Eu Declaration Of Conformity

    EU DECLARATION OF CONFORMITY Hereby, Esse-ti S.r.l. declares that the equipment type Helpy Compact-TL is in compliance with Directives 2014/33/EU - 2014/53/EU. The full text of the EU declaration of conformity is available from the following Internet address: https://www.esse-ti.it/en/dichiarazioni-di-conformita Page 30...
  • Page 31 NOTE NOTE Page 31...
  • Page 32 Esse-ti S.r.l. Via G. Capodaglio, 9 62019 Recanati (MC) – ITALY Tel. +39 071 7506066 Fax +39 071 7506057 www.esse-ti.it support@esse-ti.it...

Table of Contents