  • Page 1 Alarm system for elevators QUICK GUIDE 7IS-80466 25/05/2021...
  • Page 2 INSTALLING Internal power-supply connector Built-in backup battery connector Antenna cable connector Reset pushbutton Alarm pushbutton SIM Card slot with front panel Built-in loudspeaker connector Serial port for PC connection Micro SD Card slot RJ11 connector for local telephone Battery compartment door Terminal blocks Built-in microphone Page 2...
  • Page 3: Terminal Blocks

    LED signalling alarm / periodical test call (yellow) LED signalling GSM signal strength (green) LED signalling GSM status (red) LED signalling power supply status (blue) Terminal blocks NAME DESCRIPTION POWER SUPPLY INPUT (11-14VDC) – GIVEN ALARM INDICATOR LIGHT (output: 12VDC) RECEIVED ALARM INDICATOR LIGHT (output: 12VDC) 12VDC OUTPUT (max.
  • Page 4 NSERTING THE CARD Before inserting the SIM card, make sure the device is off and use all due precaution to avoid electrostatic discharge.  Remove the cover by unscrewing the two screws.  Push the SIM Card housing cover as indicated by the arrow OPEN until it unlocks and lift it.
  • Page 5 ONNECTING THE SPEAKER UNITS HelpyGSM comes with a built-in active speaker unit. It is also possible to connect to the HelpyGSM: up to 2 independent active speaker units up to 2 passive speaker units (or cables with microphone) combined to the integrated active speaker unit.
  • Page 6 Installation with active speaker unit in the pit SPEAKER UNIT PUSHBUTTON DEVICE terminal blocks terminal blocks ROOF HelpyGSM Built-in active speak. unit Built-in pushbutton – – Microphone cable MIC3 / ALC / – – Active speak. unit VVY / ALY / PROGRAMMING CODES "TYPE OF INSTALLATION"...
  • Page 7 ONNECTING THE EMERGENCY CALL BUTTONS Car pushbutton It is possible to connect (inside the elevator car) voltage free contact pushbuttons or powered pushbuttons.  Connect, following one of the diagrams shown below, the car pushbutton. Voltage free contact pushbuttons Powered pushbuttons (12~24Vdc) – 2 solutions INSTALLING Page 7...
  • Page 8 Other pushbuttons It is possible to use for the pit, the car-top or the landing floors, voltage free contact pushbuttons (NO).  Connect, following the diagram shown below, the other pushbuttons. Page 8 INSTALLING...
  • Page 9 ONNECTING THE INDICATOR LIGHTS The GIVEN ALARM INDICATOR LIGHT (yellow) switches on after pressing the emergency button to indicate the beginning of the alarm procedure and stays steady light until the end. The RECEIVED ALARM INDICATOR LIGHT (green) switches on when the alarm call is answered. ...
  • Page 10: Connecting The Relay

    Note: the ALZ input must be programmed as auxiliary input (by setting parameter 55). ONNECTING THE RELAY  Connect the output RL1 (normally open contact) to the external device. EPLACING BATTERY ATTENTION Only use replacement batteries supplied by Esse-ti. Page 10 INSTALLING...
  • Page 11: Wiring Diagram

    – E IRING DIAGRAM XAMPLE INSTALLING Page 11...
  • Page 12 – E IRING DIAGRAM XAMPLE Page 12 INSTALLING...
  • Page 13: Power Connection

    URNING ON Power connection  Connect the power supply cable to the 230Vac mains.  Connect an external 12Vdc power supply (min. 11Vdc, max. 14Vdc) to the power supply input of the terminal block (+ and terminals) –  Connect the built-in backup battery cable to the slot B in the picture at page 2.
  • Page 14 INIMUM OPERATIONS TO VERIFY PROPER INSTALLATION 1. PROGRAMMING  Access to programming: lift the local telephone handset and dial The programming activated message will be heard.  Program a telephone number for the emergency-call alarm: dial < telephone number > ...
  • Page 15: Resetting The Alarm

     Press to speak with the trapped person. mode: immediate and automatic two-way communication (no messages)  Answer by the called party.  Speak with the trapped person. 4. RESETTING THE ALARM Note: the alarm reset mode can be configured with the “Alarm reset mode”...
  • Page 16: Using The Reset Button

    SING THE RESET BUTTON Note: the reset operation does not alter the previously set parameters. Use of the reset pushbutton (D in the picture at page 2): Pressing shortly Allows to interrupt an alarm call. By pressing shortly you get the same result as lifting the handset of the local telephone and entering * <Password>...
  • Page 17: Basic Programming

    EXITING THE <INSTALLER or OPERATOR PASSWORD> PROGRAMMING (factory setting: SOURCE RECEIVER emergency- — call button battery USER alarms periodic automatic test ESSE-TI call … — (X…X = TELEPHONE telephone (position NUMBERS number, SIM card from 01 to (INST) max 20...
  • Page 18: Installation

    BASIC PROGRAMMING DELETING TELEPHONE ( position from 01 to NUMBER (INST) only the built-in active speaker unit built-in active speaker unit and 1 active speaker unit Number of connected active speaker built-in active speaker unit TYPE OF units and 2 active speaker units INSTALLATION connected (INST)
  • Page 19 AUTOMATIC TEST automatic test disabled DATA Enabling (INST) automatic automatic test enabled (EN 81-28:2018) test automatic test enabled (EN 81-28:2004) Manually perform a test call PROTOCOLS Esse-ti IDENTIFICATION … (identification CODE code) P100 (INST) built-in active speaker unit SPEAKER UNITS...
  • Page 20: Advanced Programming

    BASIC PROGRAMMING GENERAL loudspeaker microphone messages VOLUME (from 1 to 5; from 8 to 9; (from 1 to (INST/OPER) factory default factory 5; factory default 8) default 2) LISTEN TO THE PROGRAMMING (programming code prefix) AGAIN (INST) RESTORE FACTORY SETTINGS (INST) Advanced programming ADVANCED PROGRAMMING...
  • Page 21: Auxiliary Alarm

    ADVANCED PROGRAMMING AUXILIARY disabled alarm ALARM (INST) enabled alarm disabled alarm SIM CARD EXPIRING enabled alarm ALARM Last (INST) recharge (dd) (mm) (yy) date disabled ENABLE FILTER (INST/OPER) enabled FILTER BYPASS (seconds, from 15 to 30; 99=no bypass) (INST/OPER) FILTER INPUT normally closed NORMALLY CLOSED/OPEN...
  • Page 22 ADVANCED PROGRAMMING automatic reset ALARM RESET MODE alarm reset by “End alarm” code (INST) automatic reset with local acknowledgement “PLAY IDENTIFICATION … (from 1 to 3 digits; factory default 5) MESSAGE” CODE (INST) “COMMUNICA- TION ACTIVA- … (from 1 to 3 digits; factory default 0) TION”...
  • Page 23: Relay Setting

    ADVANCED PROGRAMMING CALL CYCLES FOR TECHNOLOGICAL (cycles, from 1 to 9; 0= 10 cycles; ALARMS AND factory default 3) TEST CALLS (INST) WAITING TIME BETWEEN TECHNOLOGICAL (minutes, from 01 to 99; OR TEST CALLS 00=30 seconds, factory default 02) TO THE SAME NUMBER (INST) AUTOMATIC...
  • Page 24 ADVANCED PROGRAMMING DTMF generated by GSM network DTMF GENERATOR DTMF generated by HelpyGSM SETTING (DTMF duration = X∙50ms; from 1 to 9; factory (INST) default 2) DISABLE ROAMING (MCC) (MNC) (INST) ENABLE ROAMING (INST) ENTER PIN CODE (WHEN PIN … (PIN) …...
  • Page 25 - set a micro SD card to use for programming, customizing the messages and updating the firmware of the HelpyGSM. e-stant can be downloaded at the following link: https://www.esse-ti.it/download/richiesta-software Programming via micro SD card The micro SD card properly set allows to:...
  • Page 26: Programming Via Sms

    Programming via SMS Programming via SMS can be performed from any mobile phone or other device that can send SMS messages. An SMS notifying the programming was performed is sent by the HelpyGSM to the number that sent the programming. ATTENTION Programmed performed via SMS sent from the Internet could not have a positive result if the...
  • Page 27 Local use In the tables: : lift the local telephone handset : lift the local telephone handset and dial to access programming LOCAL USE CONVERSATION CONVERSATION WITH THE CAR CAR SPEAKER UNIT CONVERSATION SPEAKER UNIT CONNECTED TO VVY WITH ONE SPEAKER UNIT SPEAKER UNIT CONNECTED TO VVX DEACTIVATE ALL...
  • Page 28 SIGNALS LED signalling alarm / periodical test call (yellow) Emergency-call alarm Emergency call alarm suspended Other alarms - Test call LED signalling GSM signal strength (green) No signal Low signal level (connection not guaranteed) Medium signal level Good signal level High signal level Page 28 SIGNALS...
  • Page 29 LED signalling GSM status (red) GSM module correctly registered on the network HelpyGSM registering to the GSM network – HelpyGSM not registered correctly – PIN request – PIN incorrect – Other problems Call in progress LED signalling power supply status (blue) The external power supply is connected and the battery has max capacity charge...
  • Page 30 The external power supply is disconnected and the battery guarantees up to 7-hour operation in idle state The external power supply is disconnected and the battery guarantees 2-hour operation in idle state The external power supply is disconnected and the battery guarantees 1-hour operation in idle state Given alarm indicator light (yellow)
  • Page 31: Troubleshooting

    EU D ECLARATION OF ONFORMITY Hereby, Esse-ti S.r.l. declares that the radio equipment type HelpyGSM is in compliance with Directives 2014/33/EU and 2014/53/EU. The full text of the EU declaration of conformity is available from the following Internet address: https://www.esse-ti.it/en/dichiarazioni-di-conformita...
  • Page 32 HelpyGSM edition 25/05/2021 Esse-ti S.r.l. Via G. Capodaglio, 9 62019 Recanati (MC) – ITALY Tel. +39 071 7506066 Fax +39 071 7506057 www.esse-ti.it support@esse-ti.it...