Part Names and Operating Modes
V680-HAM42-DRT

Part Names

Operation indicators
MS: ID Slave status
NS: Network status
TR: ID Tag communications status
NORMAL/ERROR: Result of communications with ID Tag
Node Address Switches
Node address switches (setting range: 00 to 63)
DeviceNet Connector
Connects to DeviceNet Master Unit.
Enclosed connector model:
FKC2.5/5-ST-5.08-RFAUM (Phoenix Contact)

Operating Modes

Mode Symbol
0
4CH
4-byte Access Mode
1
16CH
26-byte Access Mode
2
32CH
58-byte Access Mode
3
SYNC1
V600-compatible Trigger Mode, 100-ms output time
4
SYNC2
V600-compatible Trigger Mode, 500-ms output time
5
AUTO1
V600-compatible Auto Mode, 100-ms output time
6
AUTO2
V600-compatible Auto Mode, 500-ms output time
7
TEST
ID Tag Communications Test Mode (Checks standalone op-
eration of ID Slave.)
8
NOISE
Noise Measurement Mode (Measures the noise around the
Antenna.)
9
---
Setting prohibited
Note 1. The V600-compatible Trigger and Auto Modes can be used with the same I/O settings and control methods that are used with the V600-
HAM42-DRT.
2. Communications with the host device will be offline while the Communications Test Mode or Noise Measurement Mode is being used.
Commands (4-byte, 26-byte, 58-byte Access Mode)
Reading
READ
Data in the ID Tag memory is read by specifying the memory address and the number of bytes to process.
(The number of bytes can be specified using the Access Mode.)
Writing
WRITE
Data is written to the ID Tag by specifying the memory address, number of bytes to process, and the data.
(The number of bytes can be specified using the Access Mode.)
BIT SET
Previously specified bits (i.e., bits that are turned ON) are turned ON in the ID Tag address specified for BIT SET.
BIT CLEAR Previously specified bits (i.e., bits that are turned ON) are turned OFF in the ID Tag address specified for BIT CLEAR.
DATA FILL The specified continuous memory addresses in the ID Tag are filled with the same data.
V680-HAM42-DRT
OMRON
MS
T/R
NS
NORMAL/ERROR
NODE No .
1
X10
X10
FSM
SOURCE : 24VDC 0.2A
OMRON Corporation
Description
V680-HAM42-DRT, V680-HAM91/-HAM81
7
6
5
4
Data/Error Code Indicators (Two-color LED)
Data (green)
3
2
1
0
4CH
MODE
Error code (red)
16CH
NOISE
32CH
TEST
SYNC1
Mode Switch
0
AUTO2
SYNC2
OFF
AUTO1
Sets the operating mode of the ID Slave.
RFID
(Refer to the following table.)
MADE IN JAPAN
Power Supply Terminals
Connect to 24-VDC power.
Recommended Power Supply: S8VS-03024
(Manufactured by OMRON)
Enclosed connector model:
FKC2.5/3-ST-5.08-RF (Phoenix Contact)
Antenna Connector
Connects to a V680-series Antenna (V680-HS@)
Maximum number of
bytes accessible in ID Tag
Read: 4 bytes
Write: 4 bytes
Read: 26 bytes
Write: 26 bytes
Read: 58 bytes
Write: 58 bytes
Read: 3 bytes
Write: 2 bytes
---
Words allocated in Master Unit
IN: 4 words
OUT: 4 words
(PLC inputs: 64 points,
PLC outputs: 64 points)
IN: 16 words
OUT: 16 words
(PLC inputs: 256 points,
PLC outputs: 256 points)
IN: 32 words
OUT: 32 words
(PLC inputs: 512 points,
PLC outputs: 512 points)
IN: 2 words
OUT: 2 words
---
9