Omron H3DS Manual page 33

Solid-state timer h3ds series
Hide thumbs Also See for H3DS:
Table of Contents

Advertisement

■ Characteristics
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
EMC
Case color
Degree of protection
Weight
Connections
■ Block Diagram
AC (DC)
input
■ I/O Functions
Inputs
Outputs
Control output
1% max. of FS ( 1% 10 ms max. at 1.2-s range)
10%
50 ms max. of FS
0.1 s max.
0.5% max. of FS ( 0.5% 10 ms max. at 1.2-s range)
5% max. of FS ( 5% 10 ms max. at 1.2-s range)
100 M min. at 500 VDC
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min
3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) 1.5 kV (between power
supply terminals)
Malfunction: 4 kV
Destruction: 8 kV
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
2
Malfunction: 200 m/s
, 3 times each in 6 directions
Destruction: 300 m/s
2
, 3 times each in 6 directions
(EMI)
Emission Enclosure:
Emission AC Mains:
Harmonic Current:
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity Burst:
Immunity Surge:
Light gray (5Y7/1)
IP30 (IP20 for terminal block)
Approx. 70 g
Zero setting
detection
circuit
Power supply
Oscillation
circuit
circuit
---
Outputs are turned ON when the preset value is reached.
EN61812-1
EN55011 Group 1 class B
EN55011 Group 1 class B
EN61000-3-2
EN61812-1
EN61000-4-2: 6 kV contact discharge (level 3)
8 kV air discharge (level 3)
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
EN61000-4-4: 2 kV power port and output port (level 3)
1 kV control port with capacitive clamp (level 3)
EN61000-4-5: 2 kV common mode (level 3)
1 kV differential mode (level 3)
Time scale/
Indicator
unit selectors
circuit
Counting
circuit
Solid-state Two-wired Timer
Output
circuit
H3DS-X
B-41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H3ds-mH3ds-sH3ds-aH3ds-fH3ds-gH3ds-x

Table of Contents