Page 1
Solid-state Twin Timer H3DE-F Operates in flicker-OFF or flicker-ON start mode with one Unit. Independent ON- and OFF-time settings. Combinations of long ON- or OFF-time and short OFF- or ON-time setting are possible. Long time range from 0.1 s to 12 h for both ON and OFF time settings.
H3DE-F H3DE-F Specifications General Item H3DE-F Operating mode Flicker-OFF/Flicker-ON start Operating/Reset method Time-limit operation/Time-limit reset or self-reset Terminal block Clamps two 2.5 mm max. bar terminals without sleeves Terminal screw tightening torque 0.98 N m max. {approx. 10 kgf cm max.}...
Page 3
H3DE-F H3DE-F Characteristics Accuracy of operating 1% max. of FS ( 1% 10 ms max. at 1.2-s range) time Setting error 0.05 s max. of FS Influence of voltage 0.5% max. of FS ( 0.5% 10 ms max. at 1.2-s range) Influence of temperature 2% max.
H3DE-F H3DE-F Nomenclature Nameplate for user use (20 x 5.4 mm white panel) ON-time unit display window Time scale display window Time unit selector Time scale selector (select one from s, 10s, min, or h for output ON) (select 0.1 or 1)
H3DE-F H3DE-F I/O Function Inputs Outputs Control output Outputs are turned ON/OFF according to the time set by the ON-and OFF-time setting dial. Basic Operation Time Unit Selection Time Scale Selection The time unit display window for output ON is located on the upper-...
H3DE-F H3DE-F Dimensions Terminal block (black) H3DE-F Surface color: Light gray 5Y7/1 (OMRON) Terminal block (black) Installation Terminal Arrangement Note: DC supply voltage does not require the designation of polarity.
Page 7
H3DE H3DE Accessories (Order Separately) Note: The undermentioned is common for all H3DE models. Note: All units are in millimeters unless otherwise indicated. Dimensions Mounting Track PFP-100N, PFP-50N PFP-100N2 7.3 0.15 29.2 27 0.15 35 0.3 35 0.3 25 15 L: Length PFP-100N 50 cm...
H3DE H3DE Precautions Note: The undermentioned is common for all H3DE models. Changing of Setting NOTICE: Both AC and DC power supplies can be connected to the power in- Do not change the time unit, time scale, operating mode, put terminals without regarding polarity. or output type selector switch while the Timer is in opera- tion or malfunction could result.
Page 9
H3DE H3DE Switching Current vs. Ambient Temperature Contact or transistor for external input signal (When Mounting Two or More H3DE Units Side-by-Side) Mounting clearance: 50 mm min. Incorrect H3DE Power supply Mounting clearance: 10 mm Maximum range of operating ambient temperature Short-circuit current...
Page 10
H3DE H3DE Precautions for VDE Conformance The H3DE as a built-in timer conforms to VDE 0435/P2021 provided that the following conditions are satisfied: The output section of the H3DE is provided only with basic isolation. To ensure reinforced isolation required by the VDE standards, pro- vide supplementary basic isolation on the load side connected to the output.
Page 11
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. L092-E1-3C In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Supervisory Control Devices Division 28th Fl., Crystal Tower Bldg.