Characteristics
Item
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Certified standards
Weight
G3F-203SN-VD
G3F-203SLN-VD
G3F-202SN-VD
G3F-203SL-VD
G3F-203S-VD
1/2 of load power
1 ms max.
source cycle + 1 ms
max. (DC input)
3/2 of load power
source cycle + 1 ms
max. (AC input)
1/2 of load power
1/2 of load power
source cycle + 1 ms
source cycle + 1 ms
max. (DC input)
max.
3/2 of load power
source cycle + 1 ms
max. (AC input)
1.6 V (RMS) max.
5 mA max. (at
2.5 mA max. (at
100 VAC)
100 VAC)
10 mA max. (at
5 mA max. (at
200 VAC)
200 VAC)
100 M
min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
2
Destruction: 1,000 m/s
Operating: –30 C to 80 C (with no icing or condensation)
Storage:
–30 C to 100 C (with no icing or condensation)
Operating: 45% to 85%
G3F: UL508, CSA C22.2 No. 14, EN60947-4-3
G3FD: UL508, CSA C22.2 No. 14, EN60950
Approx. 50 g
G3FD-X03SN-VD
G3FD-102SN-VD
G3FD-X03S-VD
0.5 ms max.
0.5 ms max. (DC in-
put)
20 ms max. (AC input)
2 ms max.
2.5 ms max. (DC in-
put)
20 ms max. (AC input)
1.5 V max.
5 mA max. (at
0.1 mA max. (at
50 VDC)
100 VDC)
1,500 VAC, 50/60 Hz for 1 min
Solid State Relays G3@-VD
G3FD-102S-VD
0.5 ms max.
2.5 ms max.
0.1 mA max. (at
100 VDC)
G3F/G3FD
217