Troubleshooting
Message
Set parameters so that
Rectangle area +
Margin*2 > 0.
Timeout error.
Probable Cause and Remedy
Cursor frame or margin could not be set.
SWiden the cursor frame to match the margin setting or increase the margin
setting.
Transfer has been interrupted due to a timeout error for communications with
the external device.
Stop operations, turn OFF the power supply. Check that the following conditions
are true before resuming operation:
SThe RS-232C cable is correctly connected.
SThe terminal block is correctly wired.
SThe communications settings for communications with the external device have
been correctly set.
If the error still occurs after performing the above checks, the F400 unit may be
faulty. Contact your OMRON representative.