Checking Measurements; Adjusting Evaluation Criteria While Viewing Measurements - Omron F400 - 06-1999 Operation Manual

Color vision sensor
Table of Contents

Advertisement

Checking Measurements

4-1-1

Adjusting Evaluation Criteria while Viewing Measurements

This section explains how to adjust evaluation criteria in Monitor mode while display-
ing measurement results and referring to the measurement values. Press the SHIFT
+ ESC Keys, go to Display image and select the items to be displayed.
Measurement Screen Settings p. 100
Contents
of
measurement results
Scn 0BMONB
Individual region
0.Search
Judge
:
NG
Correlation : 10
Position X : 220.000
Position Y :
180.000
:Switch
Judgement/measurement results
Note
1. Press the SHIFT + Up/Down Keys to switch the display image.
2. To store a measurement image to memory, press SHIFT + ESC. The relevant
3. To perform measurement for the still image or memory image currently being dis-
4. After all measurement results have been displayed, input the next STEP signal
displayed
NG
+
settings window will be displayed.
p. 100
played, press the SHIFT + TRIG Keys. Measurement will be performed and the
measurement results will be displayed.
or press the TRIG Key. If the next STEP signal is input or the TRIG Key is pressed
while measurement results are still being displayed, the display will be inter-
rupted and the next measurement will be performed.
Overall judgement
The overall judgement will be NG if there is even just one
NG evaluation in the measurement regions or expressions.
67ms
Measurement
time
Measurement
region
Pickup frz
5-4-1 Measurement Screen Settings
Section
4-1
5-4-1
85

Advertisement

Table of Contents
loading

This manual is also suitable for:

F400

Table of Contents