Omron CJ1W-NC271 - 12-2009 Operation Manual page 567

Position control units
Table of Contents

Advertisement

List of Parameters
Param-
Parameter
Param-
eter
name
eter
No.
size
Pn00C
RS-232
2
Baud Rate
Setting
Pn00D
Reserved
---
Pn00E
Reserved
---
Pn00F
Reserved
---
Pn010
Position
2
Loop Gain
(RT)
Pn011
Speed Loop
2
Gain (RT)
Pn012
Speed Loop
2
Integration
Time Con-
stant (RT)
Pn013
Speed
2
Feedback
Filter Time
Constant
(RT)
Pn014
Torque
2
Command
Filter Time
Constant
(RT)
Pn015
Speed
2
Feedfor-
ward
Amount
(RT)
Pn016
Feed-for-
2
ward Filter
Time Con-
stant (RT)
Pn017
Reserved
---
Setting
Explanation
Sets the baud rate for RS-232 communications.
0
2,400 bps
1
4,800 bps
2
9,600 bps
3
19,200 bps
4
38,400 bps
5
57,600 bps
Do not change.
Do not change.
Do not change.
Sets the position loop responsiveness.
Increasing the gain increases position control responsiveness and
shortens stabilization time.
Oscillation or overshoot will occur if set too high. Adjust for opti-
mum responsiveness.
Sets the speed loop responsiveness.
If the Inertia Ratio (Pn020) is set correctly, this parameter is set to
the Servomotor response frequency.
Increasing the gain increases the speed control responsiveness,
but too much gain may cause oscillating.
Small gain may cause overshoot in the speed response.
Adjust for optimum responsiveness.
Adjusts the speed loop integration time constant.
Set a large value for large load inertia.
Decrease the setting for fast response with small inertia.
Set 9999 to stop integration operation while retaining the integra-
tion value. A setting of 10000 disables integration.
Sets the type of speed detection filter time constant.
Normally, use a setting of 0.
Increasing the value reduces the noise of the Servomotor but also
reduces its responsiveness.
This parameter is disabled if the Instantaneous Speed Observer
Setting (Pn027) is enabled.
Adjusts the first-order lag filter time constant for the torque com-
mand section.
The torque filter setting may reduce machine vibration.
Sets the speed feed-forward amount.
This parameter is particularly useful when fast response is
required.
Sets the time constant for the speed feed-forward first-order lag fil-
ter.
Do not change.
Appendix B
Default
Unit
Setting
setting
range
2
---
0 to 5
0
---
---
0
---
---
0
---
---
×0.1
400
0 to 30000
[1/s]
×0.1
500
1 to 30000
Hz
×0.1
200
1 to 10000
ms
0
---
0 to 5
×0.01
80
0 to 2500
ms
×0.1 % 0 to 1000
300
×0.01
100
0 to 6400
ms
0
---
---
Enable
Details
setting
Online
---
---
---
Online
Settings
can be
changed
when the
axes are
stopped
(Busy
Online
Flag for
each axis
= 0).
Online
Online
Online
Online
Online
---
539