Omron CJ1W-NC271 - 12-2009 Operation Manual page 247

Position control units
Table of Contents

Advertisement

Transferring Data
Transferring Servo Drive
Parameters
Ladder program
MOV
MOV
WRITE DATA
MOV
MOV
READ DATA
SAVE DATA
Servo Parameters are stored in internal memory of the Servo Drive connected
to the PCU and then saved in the Servo Drive's non-volatile memory. These
parameters are read/written or saved to the non-volatile memory from the
CPU Unit using the WRITE SERVO PARAMETER, READ SERVO PARAME-
TER, and SAVE SERVO PARAMETER Bits allocated in the Axis Operating
Memory Areas.
Servo Parameters for a single axis are written and read by parameter by spec-
ifying the parameter number. Parameters for different axes can be transferred
at the same time.
Servo Parameters are saved by executing WRITE DATA to write them to the
Servo Drive's non-volatile memory. Therefore, SAVE SERVO PARAMETER
must be executed for each parameter separately from writing them to the
Servo Drive's memory (WRITE SERVO PARAMETER).
Two types of Servo Parameters are transferred to the Servo Drive: online
parameters with set values that are enabled immediately after they are writ-
ten, and offline parameters, which are not enabled just by writing them. To
enable set values for offline parameters in Servo Drive operations, save the
parameters to the non-volatile memory, and then cycle the Servo Drive power.
Alternatively, execute WRITE SERVO PARAMETER/SAVE SERVO PARAME-
TER and then execute the Servo Drive's DEVICE SETUP.
When DEVICE SETUP is executed, the Servo Drive enables all the Servo
Parameters that are currently being transferred, and initializes the present
position and output signal status to set the Servo Drive.
CPU Unit
PCU
Internal memory
Powerup
Writing data
or restart
Reading data
Saving data
Section 5-1
Flash memory
219

Advertisement

Table of Contents
loading

Table of Contents