Options (Sold Separately) - Omron C200H-MC221 Specification

Motion control unit
Hide thumbs Also See for C200H-MC221:
Table of Contents

Advertisement

Product Specifications
Model number
Settings
Indicators
Connectors on front panel
Internal current consumption (supplied from
Power Supply Unit)
Dimensions
Weight (Connectors excluded)
Safety standards
Standard accessories
Cat No.

Options (Sold Separately)

Name
MC Terminal Block Conversion
Unit
MC Terminal Block Conversion
Unit Cable
Snap-on connector for
Servodriver connector on Unit
Servodriver connector on Unit
front panel (1 set provided as
standard on this Unit)
RS-232C cable and connector
for MC Support Software
Teaching Box
Teaching Box Connecting
eac
g o Co
ec
g
Cable
C bl
ROM Cassette
Applicable CPU Units
PC
CS1-series
CS1H-CPUjj
CS1G-CPUjj
C200HX/HG/HE
C200HE-CPU11/32/42 (-ZE)
C200HG-CPU33/43 (-ZE)
C200HX-CPU34/44 (-ZE)
C200HG-CPU53/63 (-ZE)
C200HX-CPU54/64 (-ZE)
C200HX-CPU65-ZE/85-ZE
C200HS
C200HS-CPU01(-j)/21(-j)/31/03/23/33
C200H
C200H-CPU01/02/03/11/21/22/23/31
Note: Restrictions on SYSMAC BUS Remote I/O Slave Racks
The maximum number of C200H Special I/O Units that can be mounted on a SYSMAC BUS Remote I/O Slave Unit differs according to
The following switches are located on the front panel.
Rotary switch: Unit number setting (0 to 8, A to E)
Slide switch: Peripheral selection switch (used for determining whether to connect
the peripheral connector to Teaching Box or MC Support Software)
The following switch is located on the rear panel.
DIP switch: Absolute encoder default setting function, software switch
enabled/disabled, Teaching Box Japanese/English mode switching
6 LED indicators: Running, error, motor rotation direction (CCW/CW)
Servodriver connector, I/O connector, peripheral connector (one each)
650 mA or less at 5 VDC (with Teaching Box connected: 850 mA or less)
200 mA or less at 24 VDC
130.0
34.5
Note: The height including the Backplane is 200 to 240 mm when the attached
connector and the recommended cable are used.
500 g max.
Conforms to UL (Class 2), CSA (Class 2), and EC directives (EMC directive,
low-voltage directive).
10126-3000VE snap-on connector for Servodrivers and 10326-42F0-008 connector
cover (manufactured by Sumitomo 3M): 1 set
Peripheral connector (10120-3000VE 20-pin connector and 10320-42F0-008
connector cover manufactured by Sumitomo 3M): 1 set
Introduction: W314, Details: W315 (suffixes omitted)
Specifications
For easier wiring of I/O connectors
For connecting the I/O connectors on the front panel of the
Unit
Soldered connector
Connector cover
Recommended cable
Peripheral connector on Unit
front panel (1 set provided as
front panel (1 set provided as
standard on this Unit)
Jogging, origin search, present value monitoring, and other
operations by means of manual commands
Teaching (taking present values into position data)
Cable length: 2 m
Cable length: 4 m
Cable length: 6 m
---
CPU Unit model
C200H-MC221
100.5 mm (H
W
D) Single-slot size
Soldered connector
Connector cover
Total number of MCUs that can be
mounted on CPU Units, Expansion
I/O Racks, and SYSMAC BUS
Remote I/O Slave Racks (see note)
8 (unit numbers 0 to 8 and A to E)
5 (unit numbers 0 to 8)
8 (unit numbers 0 to 8 and A to E)
5 (unit numbers 0 to 8)
5 (unit numbers 0 to 8)
Motion Control Unit
Model
XW2B-20J6-6
XW2Z-100J-F1
10126-3000VE (Sumitomo 3M)
10326-42F0-008 (Sumitomo 3M)
CO-DS-IREVV-SX-10P
0.18 mm
(Hitachi Cable)
10120-3000VE (Sumitomo 3M)
10320-42F0-008 (Sumitomo 3M)
CVM1-PRO01-E
CV500-CN224
CV500-CN424
CV500-CN624
CVM1-MP702
Unit location restrictions
None
None
None
None
Cannot be mounted to two
rightmost slots on CPU Rack.
2
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

C200heC200hgC200hxC2cs1 seriesC200hsC200h

Table of Contents