Download Print this page

Advertisement

Quick Links

i i B B e e d d ® ® L L o o c c a a t t o o r r
O O p p e e r r a a t t i i o o n n s s a a n n d d I I n n s s t t a a l l l l a a t t i i o o n n M M a a n n u u a a l l
5212 WM
Connected Hospital®
EN
5212-009-101 Rev AA.3
2023-04

Advertisement

loading
Need help?

Need help?

Do you have a question about the Connected Hospital iBed Locator and is the answer not in the manual?

Questions and answers

Summary of Contents for Stryker Connected Hospital iBed Locator

  • Page 1 i i B B e e d d ® ® L L o o c c a a t t o o r r O O p p e e r r a a t t i i o o n n s s a a n n d d I I n n s s t t a a l l l l a a t t i i o o n n M M a a n n u u a a l l 5212 WM Connected Hospital®...
  • Page 3 Protection against water jets For US Patents see www.stryker.com/patents Medical Electrical Equipment recognized by Underwriters Laboratories Inc for use with Stryker hospital beds in accordance with UL 60601-1 First Edition (2003) and CAN/CSA C22.2 No. 601.1-M90 with Updates 1 and 2.
  • Page 5 T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Warning/Caution/Note Definition ..........................2 Summary of safety precautions ..........................2 Introduction ................................3 Product description ..............................3 Intended use ................................3 Expected service life ...............................3...
  • Page 6 W W a a r r n n i i n n g g / / C C a a u u t t i i o o n n / / N N o o t t e e D D e e f f i i n n i i t t i i o o n n The words W W A A R R N N I I N N G G , C C A A U U T T I I O O N N , and N N O O T T E E carry special meanings and should be carefully reviewed.
  • Page 7 I I n n t t e e n n d d e e d d u u s s e e i i B B e e d d Locator is intended for use with Stryker compatible products listed in the specifications table. For further instructions, see your Operations Manual.
  • Page 8 Internally powered Wireless connection Uses Infrared (IR) LED based Stryker proprietary communication scheme Compatible products Model 3009 P P r r o o C C u u i i t t y y ® Bed Series Model FL27 I I n n T T o o u u c c h h ® Critical Care Bed Model 3002 S S 3 3 ®...
  • Page 9 Portage, MI 49002 To view your operations or maintenance manual online, see https://techweb.stryker.com/. Have the serial number (A) of your Stryker product available when calling Stryker Customer Service or Technical Support. Include the serial number in all written communication. S S e e r r i i a a l l / / i i d d e e n n t t i i f f i i c c a a t t i i o o n n n n u u m m b b e e r r l l o o c c a a t t i i o o n n The serial number and the bed bay identification number (BBID) (A) is located on the backside of the product (Figure 2).
  • Page 10 F F i i g g u u r r e e 2 2 – – S S e e r r i i a a l l / / i i d d e e n n t t i i f f i i c c a a t t i i o o n n n n u u m m b b e e r r l l o o c c a a t t i i o o n n 5212-009-101 Rev AA.3...
  • Page 11 I I n n s s t t a a l l l l a a t t i i o o n n W W a a l l l l m m o o d d u u l l e e a a s s s s e e m m b b l l y y c c h h e e c c k k l l i i s s t t Make sure that you have all the required components to install the i i B B e e d d Locator.
  • Page 12 • If mounting distance from the wall (C) is required, use the optional Wall Module Spacer Kit (5212-700-003) to mount the i i B B e e d d Locator. 1/2” • Minimum 4” • Maximim 5” F F i i g g u u r r e e 3 3 – – M M o o u u n n t t i i n n g g s s p p e e c c i i f f i i c c a a t t i i o o n n s s 3.
  • Page 13 7. Insert three AA alkaline batteries (not included) into the wall module (E). N N o o t t e e • Do not use rechargeable batteries. • For best results, purchase industrial brand name batteries. 8. Using a #2 Phillips screwdriver, install three screws (C) to secure the battery door (D) to the wall module (E). 9.
  • Page 14 F F i i g g u u r r e e 5 5 – – M M o o u u n n t t i i n n g g w w i i t t h h w w a a l l l l s s p p a a c c e e r r 4.
  • Page 15 I I n n s s t t a a l l l l a a t t i i o o n n c c h h e e c c k k l l i i s s t t Follow this checklist with Model 5212 i i B B e e d d Locator: Confirm that you do not have any unused components after you install.
  • Page 16 This process repeats anytime the product is connected. • After seven days, i i B B e e d d Locator wakes up and sends its BBID to the Stryker compatible product to share the location. The product returns to sleep mode.
  • Page 17 S S e e r r v v i i c c e e R R e e p p l l a a c c i i n n g g t t h h e e b b a a t t t t e e r r i i e e s s W W A A R R N N I I N N G G •...
  • Page 18 Remove product from service before you perform the preventive maintenance inspection. Check all items listed during annual preventive maintenance for all Stryker Medical products. You may need to perform preventive maintenance checks more often based on your level of product usage. Service only by qualified personnel.
  • Page 19 C C l l e e a a n n i i n n g g C C A A U U T T I I O O N N • Do not clean, disinfect, service, or perform maintenance while the product is in use. •...
  • Page 20 D D i i s s i i n n f f e e c c t t i i n n g g C C A A U U T T I I O O N N • Do not clean, disinfect, service, or perform maintenance while the product is in use. •...
  • Page 21 E E M M C C i i n n f f o o r r m m a a t t i i o o n n G G u u i i d d a a n n c c e e a a n n d d m m a a n n u u f f a a c c t t u u r r e e r r ’ ’ s s d d e e c c l l a a r r a a t t i i o o n n - - e e l l e e c c t t r r o o m m a a g g n n e e t t i i c c e e m m i i s s s s i i o o n n s s The Model 5212 i i B B e e d d Locator is intended for use in the electromagnetic environment specified below.
  • Page 22 G G u u i i d d a a n n c c e e a a n n d d m m a a n n u u f f a a c c t t u u r r e e r r ’ ’ s s d d e e c c l l a a r r a a t t i i o o n n - - e e l l e e c c t t r r o o m m a a g g n n e e t t i i c c i i m m m m u u n n i i t t y y Floors should be wood, concrete or ceramic tile.
  • Page 23 G G u u i i d d a a n n c c e e a a n n d d m m a a n n u u f f a a c c t t u u r r e e r r ’ ’ s s d d e e c c l l a a r r a a t t i i o o n n - - e e l l e e c c t t r r o o m m a a g g n n e e t t i i c c i i m m m m u u n n i i t t y y N N o o t t e e 1 1 : : At 80 MHz and 800 MHz, the higher frequency range applies.
  • Page 24 B B e e d d L L o o c c a a t t o o r r I I D D n n u u m m b b e e r r N N o o t t e e • Give this form to your Stryker Technology Specialist or your Network Administrator so they can create the associations on the server.
  • Page 26 Stryker Medical 3800 E. Centre Avenue Portage, MI 49002 5212-009-101 Rev AA.3 2023-04 WCR: AA.21...

This manual is also suitable for:

5212 wmIbed locator