D5FSC(LC)AH: Owner's Manual

OPERATION INSTRUCTIONS

NOTES:
• Different models have different front panel and display window.
Not all the indicators describing below are available for the air
conditioner you purchased. Check the indoor display window of
the unit you purchased.
• Illustrations in this manual are for explanatory purposes. The
actual shape of your indoor unit may be slightly different. The
actual shape shall prevail.
• This display panel on the indoor unit can be used to operate the
unit in case the remote control has been misplaced or is out of
batteries.
Louver
LED display
Timer
indicator
Operation
indicator
Fig. 11 —Indoor Unit Display
• FORCED COOL mode: In FORCED COOL mode, the Operation
light flashes. The system will then turn to AUTO after it has cooled
with a high wind speed for 30 minutes. The remote control will be
disabled during this operation.
• OFF mode: When the display panel is turned off, the unit turns off
and the remote control is re-enabled.
Other Features
NOTE: Every time the unit is powered on, a buzzing sound will be
heard to indicate that the product has been powered on
normally. If there is no sound, it is possible that the unit is
abnormal. Power on again or check the circuit.
The actual functions are subject to the product you
purchased, check the indoor display and remote control of
your AC. See the <Remote Controller Manual> for more
features.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Display panel
Corner air outlet
Air inlet
Alarm indicator
When wireless control
feature is activated
PRE-DEF indicator
(pre-heating/defrost)
Default Setting
When the unit restarts after a power failure, it will default to the factory
settings
(AUTO mode, AUTO fan, 76°F (24°C)). This may cause inconsistencies
on the remote control and unit panel. Use your remote control to update
the status.
Auto-Restart
In case of power failure, the system will immediately stop. When power
returns, the Operation light on the indoor unit will flash. To restart the
unit, press the ON/OFF button on the remote control. If the system has an
auto restart function, the unit will restart using the same settings.
Three-Minute Protection Feature
A protection feature prevents the unit from being activated for
approximately 3 minutes when it restarts immediately after operation.
Louver Angle Memory Function
Some models are designed with a louver angle memory function. When
the unit restarts after a power failure, the angle of the horizontal louvers
will automatically return to the previous position.
The angle of the horizontal louver should not be set too small as
condensation may form and drip into the machine. To reset the louver,
press the manual button, which will reset the horizontal louver settings.
Heat Exchanger Dust Removal Function
This feature helps keep the outdoor coil cleaner and may extend the
duration between regular maintenance intervals depending on local
conditions. When the unit is turned off, a 10 seconds delay occurs and the
outdoor fan runs in reverse rotation for 70 seconds to blow off loose
accumulated dust and debris.
Sleep Operation
The SLEEP function is used to decrease energy use while you sleep (and
you do not need the same temperature settings to stay comfortable). This
function can only be activated via remote control. And the Sleep function
is not available in FAN or DRY mode.
Press the SLEEP button when you are ready to go to sleep. When in
COOL mode, the unit will increase the temperature by 2°F (1°C) after 1
hour, and will increase an additional 2°F (1°C) after another hour.
When in HEAT mode, the unit will decrease the temperature by 2°F (1°C)
after 1 hour, and will decrease an additional 2°F (1°C) after another hour.
The sleep feature will stop after 8 hours and the system will keep running
with final situation.
Cool mode(+1 C/2 F) per hour
Set
temperature
Heat mode( -1 C/2 F) per hour
Fig. 12 —Sleep Operation