In connection to the terminal block of the controller, mount a single wire or stranded wire (lead
insert it to the back of the hole.
When it is correctly inserted, it is locked and not removed by pulling. If it is pulled with strong
force, it may be disconnected.
To connect a stranded wire (lead wire) without using a ferrule (sleeve) terminal, mount it
while holding the release button.
To disconnect a single wire or stranded wire (lead wire), pull out the single wire or stranded
wire (lead wire) while pressing the release button.
2
0.2 to 1.5mm
MJE-SQ4C11 No. 0095-80V
(AWG 24 to 16) is recommend for single wire or stranded wire (lead wire).
Flathead screwdriver
Lead wire
Ferrule (sleeve) terminal
(Purchase separately.)
Release button
Wiring
17