Models: DLI-E30ASX, DLI-E36ASX
Downdraft Hood
For use with these blowers
(purchase blowers separately):
Model DBI-600A - Internal
Models CBE-1000 - External
Models PBN-1000A - In-Line
Français p. 35
APR19.0101
Español p. 69
READ AND SAVE THESE INSTRUCTIONS
Register your product online at: www.zephyronline.com

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr DLI-E30ASX

  • Page 1 Models: DLI-E30ASX, DLI-E36ASX Downdraft Hood For use with these blowers (purchase blowers separately): Model DBI-600A - Internal Models CBE-1000 - External Models PBN-1000A - In-Line Français p. 35 APR19.0101 Español p. 69 READ AND SAVE THESE INSTRUCTIONS Register your product online at: www.zephyronline.com...
  • Page 2: Table Of Contents

    Table of Contents Safety Information ....................................3 Contents ........................................4 Specifications ......................................4 Tools Needed ......................................4 Planning Before You Begin ....................................5 Taking Measurements..................................5 Ducting Configurations ..................................5 Cabinet Cutouts ....................................10 Preparing the Downdraft Side or Rear Ducting ..................................12 Front Ducting .....................................
  • Page 3: Safety Information

    Safety Information WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number on the back page.
  • Page 4: Contents

    Contents ELECTRICAL SPECIFICATIONS Model DBI-600A - Internal 120 VAC • 60 Hz • 3.0 A Models CBE-1000 - Exterior Models PBN-1000A - In-Line 120 VAC • 60 Hz • 6.0 A (max.) Part Description Quantity Part Description Quantity Upper support bracket (left) Flip door Downdraft ventilator housing LED light strip...
  • Page 5: Planning

    Planning Before You Begin Taking Measurements Due to its flexible design, this downdraft system can be used to exhaust airborne contaminants when cooking with a variety of gas • Refer to the cooktop installation instructions for dimensions or electric cooking appliances - including cooktops, rangetops, of cooktop, countertop cut-out, and cabinet requirements.
  • Page 6 Planning Ducting Configurations (continued) Front Exhaust with DBI-600A Blower (through cabinet) Downdraft DBI-600A Blower 8" Straight Duct Electrical Panel 8" Round Elbow Front Exhaust with DBI-600A Blower (through Front Exhaust with DBI-600A Blower and cabinet) and Recirculating Kit Recirculating Kit Downdraft DBI-600A Blower Downdraft...
  • Page 7 Planning Ducting Configurations (continued) Side Exhaust with DBI-600A Blower and Side Exhaust with DBI-600A Blower Recirculating Kit 1-7/8" to 8" Round Transition Downdraft Downdraft 1-7/8" to 8" Round Transition DBI-600A 8" Straight Duct Blower DBI-600A Blower 8" Straight Duct 8" Straight Duct 8"...
  • Page 8 Planning Ducting Configurations (continued) Front Exhaust with Remote Blower Downdraft 10" Straight Duct * To one of the following: Model CBE-1000 External Blower • Model PBN-1000A In-line Blower 10" Round Elbow Note: External or in-line blowers require 10" ducting. Side Exhaust with Remote Blower 10"...
  • Page 9 Planning Ducting Configurations (continued) Rear Exhaust with Remote Blower Downdraft 10" Round Elbow 1-7/8" to 10" Round Transition * To one of the following: 10"Straight Duct Model CBE-1000 External Blower • Model PBN-1000A In-line Blower Note: External or in-line blowers require 10" ducting. Below Exhaust with Remote Blower Downdraft 1-7/8"...
  • Page 10: Cabinet Cutouts

    Planning Cabinet Cutouts Below, Side or Rear Ducting Cutouts CAUTION BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with floor joists, wall studs, electrical wiring, or plumbing. / 8 " / 8 " 5 - 7 5 - 7 ( 1 4 ( 1 4 Use the dimensions in illustrations to help plan how and where to...
  • Page 11 Planning Cabinet Cutouts (continued) 10" External or In-line Blower Ducting Cutout DBI-600A Blower Ducting Cutout Appliance Appliance Cutout Cutout n t e n t e r l i r l i d r a d r a Ø8" (20.3 cm) Ø10"...
  • Page 12: Preparing The Downdraft

    Preparing the Downdraft Side or Rear Ducting Front Ducting Remove a discharge cover (G) from sides or rear of downdraft (B). Remove front panel cover (H) from downdraft (B). Note: Only remove one cover. Install a transition and rectangular ductwork to downdraft (B). Install 8"...
  • Page 13: Electrical Panel In Remote Location

    Preparing the Downdraft Electrical Panel in Remote Location Final Assembly Remove electrical panel (I) from downdraft (B). Electrical panel connector Attach previously removed lower support legs (E) to downdraft (B) using one cable legth is 2 feet. Optional 5 foot cable extension available. nut for each leg.
  • Page 14: Installation

    Gas Cooktop seal kit is recommended if installing a gas cooktop. See Optional Accessory page for more information. Place appliance. Note: Cook top shown. Rangetop Center template against the back flange and mark downdraft opening. A = 1-7/8" B = 27-1/4" DLI-E30ASX, 33-1/4" DLI-E36ASX...
  • Page 15: Install Housing Into Cabinet

    Installation Cutting Counter Top Opening Install Housing into Cabinet (continued) (continued) Remove cook top/appliance and cut opening. Attach support legs (E) to bottom of cabinet with two screws (AA) per leg. Tighten hex screws. Note: If cabinet bottom is removed, use blocks Install Housing into Cabinet as spacers between floor and support legs.
  • Page 16: Install Finishing Trim

    Installation Installing Finish Trim Installing Finish Trim (continued) TOP VIEW Washer 1/16" Gap 1/16" Gap Trim Door Retaining Retaining Washer Washer Flush Place retaining washer on left trim cap (C). Insert hinge pin into slot of the flip door. Position left trim cap and flip door. Align trim caps and complete CAUTION assembly by tightening trim cap nut.
  • Page 17: Electrical Wiring Installation

    Electrical Wiring Installation 600 CFM WIRING SET UP DBI-600A Blower only White (common) White (common) Blue (low) Blue (low) Lift DBI-600A Grey (med.) Red (med.) Downdraft Blower CAUTION Black (high) Black (high) Orange (high) Green (ground) Green (ground) All electrical wiring should be done by a qualified Orange (Cap Off) person(s) in accordance with all applicable codes 400 CFM WIRING SET UP...
  • Page 18: Exterior Or In-Line Blower Only

    Electrical Wiring Installation Exterior or In-Line Blower only White (Common) White (Common) CAUTION Blue (Low) Red (Low) Lift Remote Gray (Med.) Blue (Med.) All electrical wiring should be done by a qualified Downdraft Blower Black (High) Black (High) person(s) in accordance with all applicable codes Orange (High) and standards.
  • Page 19: Appliance Installation/Operation

    Appliance Installation/Operation Install Cooking Appliance Note: Accurate alignment of cooking appliance and downdraft is necessary to ensure that there is no interference when air vent is 1. Align the cooking appliance with downdraft and fasten appliance raised and lowered. There should be a gap of 1/32 " - 1/16 " between in place following appliance instructions.
  • Page 20: Use And Care

    Use and Care Cooking WARNING CAUTION Always disconnect electric power supply before cleaning and/or servicing unit. To clean inside chimney: Lift FRONT PANEL up and out and take out the GREASE FILTERS. Always turn the downdraft blower on before you begin cooking Use a mild detergent.
  • Page 21: Optional Accessories

    Optional Accessories Optional Accessories Accessory Description Accessory Description EXTENSION CABLE - 5-FT. Model DDA-0002 REMOTE UP/DOWN CONTROL MODEL 11030132 Use when you cannot reach the UP/ Use where electrical panel is remotely DOWN Button on the downdraft chimney. mounted. Extends electrical panel cable an additional 5 feet.
  • Page 22 Optional Accessories Optional Accessories (continued) Accessory Description MODEL DDE-0001 END CAP TRIM EXTENSION +1" WIDTH - LH & RH Use left and right to increase the overall trim width by 1". MODEL 54190053 FRONT PANEL ROUGH-IN PLATE - 8" ROUND Use where 8"...
  • Page 23: Blower Duct Routing Configurations A - H

    Blower duct routing configuration A Internal Blower (DBI-600A) - Front Mounted to Downdraft MODEL DBI-600 Internal Blower (sold separately) (“Down” discharge shown. Blower can also be rotated for “Left” or “Right” discharge.) 8-inch Round Straight Duct* 8-inch Round Wall Cap* Electrical Panel (Mount in remote location) 8-inch Round Elbow*...
  • Page 24 Blower duct routing configuration B Internal Blower (DBI-600A) - Remote Mounted - Front Outlet MODEL 54190053 8-inch Round Front Rough-in Plate (sold separately) 8-inch Round Elbow* Electrical Panel (Can be mounted in remote location) 8-inch Round Straight Duct* MODEL 11030132 5-foot Extension Cable (sold separately) MODEL DBI-600A...
  • Page 25 Blower duct routing configuration C Internal Blower (DBI-600A) - Remote Mounted - Side Outlet MODEL AK00072 1-7/8-inch x 19-inch Rectangular Transition MODEL AK00080 (sold separately) 1-7/8-inch x 19-inch (Only required to Rectangular Duct extend duct along (sold separately) back of cabinet.) (Only required to MODEL AK00070 extend duct along...
  • Page 26 Blower duct routing configuration D Internal Blower (DBI-600A) - Remote Mounted - Rear Outlet MODEL AK00080 1-7/8-inch x 19-inch MODEL AK00070 Rectangular Duct 1-7/8-inch to 8-inch (sold separately) Round Transition (sold separately) MODEL AK00072 MODEL DBI-600A 1-7/8-inch x 19-inch Internal Blower Rectangular Transition (sold separately) (sold separately)
  • Page 27 Blower duct routing configuration E Internal Blower (DBI-600A) - Remote Mounted - Below Outlet MODEL 11030132 5-foot Extension Cable (sold separately) (Only required if electrical panel is mounted in a remote location - more than 2-feet away from downdraft. Electrical Panel Use up to 2 extension cables (Can be mounted in connected together.)
  • Page 28 Blower duct routing configuration F External or In-Line Blower - Front Outlet 54190054 MODEL 10-inch Round Front Rough-in Plate MODEL 11030132 (sold separately) 5-foot Extension Cable (sold separately) (Only required if Electrical Panel is mounted in a remote location - more than 2-feet away from downdraft.
  • Page 29 Blower duct routing configuration G External or In-Line Blower - Side or Rear Outlet MODEL AK00072 MODEL AK00080 1-7/8-inch x 19-inch 1-7/8-inch x 19-inch Rectangular Transition MODEL 11030132 Rectangular Duct (sold separately) MODEL AK00071 5-foot Extension Cable (sold separately) (Only required to extend 1-7/8-inch to 10-inch (sold separately) (Only required to...
  • Page 30 Blower duct routing configuration H External or In-Line Blower - Below Outlet MODEL 11030132 5-foot Extension Cable (sold separately) (Only required if electrical panel is mounted in a remote location - more than 2-feet away from downdraft. Electrical Panel Use up to 2 extension cables (Can be mounted in connected together.) remote location.)
  • Page 31: Wiring Diagram

    Wiring Diagram...
  • Page 32: Dimensional Drawing

    Dimensional Drawing 18” 15-1/8” 6-1/4” 29-3/8”...
  • Page 33: Warranty

    Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...