Contents Of Display; Note On Display Of Temperatures; Parameter Programming Procedure - Smeg CWC 611 User Manual

Table of Contents

Advertisement

Using the buttons
Button
Display of temperatures in
Boiler (L3) and tank (L1)
Scroll through Setup
options (2)
Set Regeneration
(mod. with softener only)
Set Short Programme
Set Medium Programme
Set Long Programme
Set P0
1) Starting from appliance in "OF" status
2) From setup menu only.
3) Restores the default parameters, for new settings see point (6.3)
A series of operations can be carried out when the dishwasher is first installed to customise it to the user's requirements.

6.1 Contents of display

The two digits provide the following information:
Appliance off but powered up: all decimal points on both digits
Appliance on and ready for use : Tank temperature
Washing phase (programme running, washing pump in operation): Tank temperature
Rinsing phase (programme running, washing pump stopped): Boiler temperature
Programming phase: See parameter programming section
Error message: See error messages section

6.2 Note on display of temperatures

Temperatures shown on the display might not indicate the actual temperature in the tank and/or boiler during heating -
wait about 1' after the heating elements switch off to see the real temperature.

6.3 Parameter programming procedure

To modify the parameters, proceed as follows starting with the appliance in "OF" status
1) switch the appliance using the On/OF button
2) hold down the
and press it again.
3) Press the pump-out button
4) Modify the parameter by pressing button P1
5) During setup operations, Led L1 indicates that the display is showing the description of the parameter, while Led L3
indicates that its value is being displayed (the two alternate)
6) Select the other parameters for modification in the same way and proceed as described above
7) After setting all the appliance parameters, press the
Short press
On/OF
Set Pump-out
Start Regeneration
Start Short Programme
Start Medium Programme
Start Long Programme
Empty tank
Peristaltic pumps in Manual
mode to prime pipes
button for about 4/5 seconds, until Led L6 goes out and then lights up again, then release the button
to scroll through the parameters for modification
CWC 611
Pressed for 2"
Pressed for 5" Long press, release, press again
Start Pump-out
Start P0
button to quit the setup function.
9
Setup Menu (1)
Start Test (1)
Reset to DEFAULT
parameters (3)
Technician user only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cwg411mdaus-2