6.14  Service setting (for After‐Sales Service only) 
 
6.15   Starting the peristaltic pumps – rapid filling of detergent and rinse aid 
delivery circuit. 
Perform after the parameter modification procedure explained in the previous point. 
Indicator lights showing:    off;   green;   orange; 
 
With  the  dishwasher  powered  up,  access  "programming 
mode" by pressing the on/off  button for a few seconds; at 
the  "beep",  release  the  button  and  press  it  again  quickly 
within 0.5 seconds. 
The  peristaltic  pumps  continue  to  operate  until  the  same 
button is pressed again. The rinse aid and detergent symbol 
lights remain on as long as the pumps are on; bear in mind 
that the rinse aid peristaltic pump fills the circuit in about 7 
minutes, while for the detergent it only takes 2 minutes. 
The dishwasher is able to identify a number of malfunctions and show them on the display. 
If the problem persists after the dishwasher has been switched off and back on, proceed as described 
below: 
 
The anti‐flooding system has been 
Err01 
activated (for the relevant models 
only). 
Err04  Tank temperature probe malfunction 
Err05  Tank water filling malfunction 
7 MALFUNCTIONS SHOWN ON THE DISPLAY (FOR
THE TECHNICIAN)
‐ CW 520/530 
See information on Smegtech 
 flashing. 
Large water leak: check the origin of the problem. 
Tank temperature probe disconnected or not 
working. 
The tank does not fill within the allowed time: check 
water intake tap, dynamic pressure in intake system, 
cleaning  of  water  intake  filter,  possible  damage  to 
21 
 