Instructions For Technical Staff; Plumbing Hookup - Smeg CW520 Manual

Professional dishwasher
Table of Contents

Advertisement

 
 
 POSITIONING: 
 
Caution: the indoor system and premises in which equipment for institutions is installed 
 
must comply with the relevant regulations. 
The manufacturer declines all liability for direct or indirect injury or damage deriving from failure 
to comply with these regulations. 
Before  installation,  check  that  there  are  no  objects  or  materials  in  the  vicinity  which  may  be 
damaged by steam or splashes of washing solution, or that any such items are suitably protected.  
Place the dishwasher in the chosen point and remove the protective film. 
Level the dishwasher (with the aid of a spirit level) on its adjustable feet to ensure that it is stable; 
all other mounting solutions must be approved by the manufacturer. 
 
 
4.1 Plumbing hookup 
Water supply and drain hookup 
 
The water pipelines and electricity supply cable lead out of the bottom right‐
hand corner of the appliance. Connect the water intake hose to a connector 
with  ¾"  gas  threaded  fitting,  fitting  the  filter  A  provided  (in  models  with 
aquastop, the filter and ring‐nut form a single unit). 
The connection to the water mains must only be made with new hoses; the 
use of old or worn hoses is not permitted. 
The  dynamic  water  supply  pressure  must  be  between  1  and  6  bar;  if  it  is  higher,  installation  of  a 
pressure reducer is necessary.  
It is essential to fit a main stop tap on the water intake deliver pipeline; the tap must be accessible 
after  installation  of  the  appliance,  so  do  not  install  it  behind  the  dishwasher.  The  stated  cycle 
duration  applies  to  appliances  supplied  with  hot  water  >50°C<60°C.  If  the  dishwasher  is  supplied 
with cold water, the cycle duration might increase depending on the intake water temperature. The 
dishwasher is fitted with a drain pump and can operate with drain connections on the floor or wall.  
Refer to the connection diagram for the maximum permitted height of wall drains – (see TECHNICAL 
DATA) 
 
Caution: make sure that the intake and drain hoses are not bent, constricted or crushed 
after installation. 
 
 
 
When  installing  the  drain  hose  to  a  siphon  with  valve,  the  maximum  height  of  the  drain  outlet  is 
reduced to 600 mm. 

4 INSTRUCTIONS FOR TECHNICAL STAFF