POSITIONING:
Caution: the indoor system and premises in which equipment for institutions is installed
must comply with the relevant regulations.
The manufacturer declines all liability for direct or indirect injury or damage deriving from failure
to comply with these regulations.
Before installation, check that there are no objects or materials in the vicinity which may be
damaged by steam or splashes of washing solution, or that any such items are suitably protected.
Place the dishwasher in the chosen point and remove the protective film.
Level the dishwasher (with the aid of a spirit level) on its adjustable feet to ensure that it is stable;
all other mounting solutions must be approved by the manufacturer.
4 INSTRUCTIONS FOR TECHNICAL STAFF
4.1 Plumbing hookup
Water supply and drain connection
The water pipelines and electricity supply cable lead out of the bottom right‐
hand corner of the appliance. Connect the water intake hose to a connector
with ¾" gas threaded fitting, fitting the filter A provided (in models with
aquastop, the filter and ring‐nut form a single unit).
The connection to the water mains must only be made with new hoses; the
use of old or worn hoses is not permitted.
The dynamic water supply pressure must be between 2 and 6 bar; if it is higher a pressure reducer
must be installed. If the pressure is less than 2.5 bar it might be necessary to fit a special pump on
the appliance to ensure optimal performance. Contact the After‐Sales Service.
It is essential to fit a main stop tap on the water intake deliver pipeline; the tap must be accessible
after installation of the appliance, so do not install it behind the dishwasher. The stated cycle
duration applies to appliances supplied with hot water >50°C<60°C If the dishwasher is supplied with
cold water, the cycle duration might increase depending on the intake water temperature.
‐ CW 510/D/SD
CW 510M/MD/MSD
9