Hot-swappable redundant power
supply module (optional)
Note: The Acer Altos G500 system supports the installation of a
280-watt fixed power supply module while the Acer Altos G610
model accepts two 337-watt hot-swappable redundant power
supply modules.
The Acer Altos G610 model's power subsystem consists of two hot-
swappable power supply module bays that accepts two 337-watt hot-
swappable redundant power supply modules. A redundant power
configuration enables a fully-configured system to continue running
even if one power supply fails.
Removing a 337-watt hot-swappable
redundant power supply module
1
Remove the screw of the power supply module using a flat
screwdriver.
2
Lift up the module handle.
3
Push the lock with your thumb to release the power supply
module.