Graham Field Lumex FR587WH Series Assembly And Operating Instructions Manual

Graham Field Lumex FR587WH Series Assembly And Operating Instructions Manual

Deluxe clinical care recliner

Advertisement

Quick Links

Series FR587W Deluxe Clinical Care Recliner,
Extra Wide
Series FR587WH Deluxe Clinical Care Recliner,
Extra Wide, with Heat and Massage
Series FR587WHO Deluxe Clinical Care Recliner,
Extra Wide, with Heat Only
ASSEM BLY A N D O PERAT ING
IN STR U CT IONS
SAVE THIS MANUAL FOR FUTURE USE.
LX_FR587W-INS-LAB-RevK22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lumex FR587WH Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Graham Field Lumex FR587WH Series

  • Page 1 Series FR587W Deluxe Clinical Care Recliner, Extra Wide Series FR587WH Deluxe Clinical Care Recliner, Extra Wide, with Heat and Massage Series FR587WHO Deluxe Clinical Care Recliner, Extra Wide, with Heat Only ASSEM BLY A N D O PERAT ING IN STR U CT IONS SAVE THIS MANUAL FOR FUTURE USE.
  • Page 2: Table Of Contents

    CONTENTS INTRODUCTION ...................................3 INTENDED USE ................................3 IMPORTANT SAFETY PRECAUTIONS—READ BEFORE USE ..................3 WARNINGS ................................3 ASSEMBLY ....................................5 UNPACKING ...................................5 UPHOLSTERED BACK ASSEMBLY ........................5 OPERATION ..................................8 TENTE CASTERS ................................8 ® SIDE TABLE OPERATION ..............................9 SIDE PANEL OPERATION ............................10 RECLINER OPERATION ...............................11 FIRST POSITION (UPRIGHT POSITION) ......................11 SECOND POSITION (FIRST RECLINE POSITION) ....................11 THIRD POSITION (SECOND RECLINE POSITION) .....................12 TRENDELENBURG POSITION (ALSO KNOWN AS SHOCK POSITION) ............12...
  • Page 3: Introduction

    INTRODUCTION This manual contains assembly, operation, and maintenance instructions for the Lumex Clinical Care Recliner Series FR587W (Models FR587W, FR587WH, and FR587WHO). Read the entire manual carefully before using your recliner, and refer to it during use if you have questions. If you have further questions, please call Graham-Field / Lumex Technical Support at 1.770.368.4700.
  • Page 4 WARNING: This product has a maximum weight capacity of 450 lb (204.1 kg), EVENLY DISTRIBUTED. WARNING: Casters must be locked at all times, except during transport. WARNING: Unauthorized modification of your recliner or the use of non-Lumex replacement parts may change the structure of the recliner and could create a hazardous condition, which may result in serious injury and will void the warranty.
  • Page 5: Assembly

    ASSEMBLY UNPACKING 1. Check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field authorized distributor. 2. Remove all packaging materials from recliner base. upholstered back upholstered seat upholstered armrest padded push handle gas spring...
  • Page 6 3. Remove cardboard shipping retainers and tape from around gas spring cylinders. Rotate the hinge section on the gas spring so that it is perpendicular to the upholstered back, as shown at right. gas spring hinge Rotate HInge panel tabs side panel 4.
  • Page 7 8. Raise the upholstered back to vertical position. Tuck the plastic skirt at rear of upholstered back behind seat frame crossbrace. Align the hinges at the bottom of the gas springs with the holes in the U-brackets on the seat frame crossbrace.
  • Page 8: Operation

    OPERATION WARNING: Disconnection of the device: In case of emergency, always disconnect the device by removing the power cord plug from the power outlet. TENTE CASTERS ® WARNING: Casters must be locked at all times, except during transport. black actuator tab green actuator tab All Lumex Clinical Care Recliners now feature the latest design, all-plastic casters from TENTE.
  • Page 9: Side Table Operation

    SIDE TABLE OPERATION side table (disengaged position) armrest To raise table: Raise the side table all the way up and slide in toward the armrest until tabs engage slots " clevis pin attachment in mount bracket. Press down side table lightly on table to ensure locking (engaged position) side table...
  • Page 10: Side Panel Operation

    SIDE PANEL OPERATION panel tabs For easy cleaning and access to the side and underside of the recliner, side panel Lumex Clinical Care Recliners feature easy-to-remove side panels. To remove side panel: Depress the two push buttons located on the lower sides of frame. Pull side panel gently away and down from frame.
  • Page 11: Recliner Operation

    RECLINER OPERATION The Lumex Series FR587W Recliner features three positions for patient comfort. The fourth position is a Trendelenburg (or Shock Position) that must be activated by a caregiver. The Trendelenburg Position CANNOT be activated by a patient while in the recliner. In addition, the Series FR587W features a back that can be repositioned via the adjustment lever located on the push handle on the back of the recliner.
  • Page 12: Third Position (Second Recline Position)

    Third Position (Second Recline Position) The third position is the Second Recline Position and is also known as the “Full Recline” position. This position is ideal for patient treatment, rest and reading. To Achieve Third Position / Second Recline Position: First Recline Position (TV Position) •...
  • Page 13: Gas Spring Troubleshooting Guide

    GAS SPRING TROUBLESHOOTING GUIDE Info: gas springs have been pre-adjusted at factory The gas spring on your recliner provides counterbalancing forces, and is self-locking for infinite, precise positioning. Unlocking the gas spring is controlled by actuating the lever located on the padded push handle on the back of the recliner.
  • Page 14: Recliners With Heat And Massage Or Heat Only Feature

    RECLINERS WITH HEAT AND MASSAGE OR HEAT ONLY FEATURE HEAT AND MASSAGE: FR587WH HEAT ONLY: FR587WHO INSTALLATION AND OPERATING GUIDE WARNING: Important! Read and understand these instructions before assembling or using the Lumex Specialty Healthcare Seating Heat and Massage / Heat Only Unit. If you do not understand any part of these warnings, cautions or instructions, contact a healthcare professional for direction in the use of this product.
  • Page 15: Heat And Massage / Heat Only Installation Instructions

    Handheld Heat & Massage Power Cord Handheld Heat Only Power Cord Pendant Connectors Connector Pendant Connectors Connector Connector Connector Heat and Massage Feature — Heat Only Feature — Control Module and Transformer Unit Control Module and Transformer Unit Showing All Connections Correctly Made Showing All Connections Correctly Made 2.
  • Page 16 2. Remove the left side table, shown at right, from the recliner to ball lock pin left side table prevent damage to it during setup: Withdraw the ball lock pin, shown at right, and set ball lock pin and table aside. 3. Place a protective cover or drop cloth on your workbench or floor to protect the recliner frame finish and upholstery.
  • Page 17: Heat And Massage / Heat Only Unit Operation Instructions

    Heat and Massage / Heat Only Unit Operation Instructions 1. Plug the power cord into any grounded outlet. Handheld Pendant Handheld Pendant Heat and Massage Heat Only 2. The Heat and Massage / Heat Only Unit is operated using the Handheld Pendant, shown above. HIGH HEAT PRESS 1 TIME MEDIUM HEAT...
  • Page 18 4. Heat and Massage MASSAGE Option: Press the MASSAGE switch to start this function. The Massage Function Settings are as follows: a) Press selector switch for Setting 1: Gentle Lower Back Massage. b) Press selector switch AGAIN for Setting 2: Firm Lower Back Massage. c) Press selector switch AGAIN for Setting 3: Gentle Upper and Lower Back Massage.
  • Page 19: Heat And Massage / Heat Only Unit Troubleshooting Guide

    Heat and Massage / Heat Only Unit Troubleshooting Guide The cables and connections need to be validated. This will require the services of a maintenance person and a clear working area. 1. INSPECTION: Perform the following checks. If a working recliner of the same model is available, use it for comparison.
  • Page 20: Care And Maintenance

    CARE AND MAINTENANCE WARNING: Inspect all components periodically and replace as needed. EVERY THREE MONTHS • Check and clean casters. • Tighten bolts in each leg that secure caster into frame. • Check caster brakes. • Check and clean lock recline mechanism. •...
  • Page 21: Cdc Recommendations

    Abrasion test results exceeding ACT Performance Guidelines are not an indicator of product lifespan. Multiple factors affect fabric durability and appearance retention. This information is not a guarantee and does not relieve the user from the responsibility of the proper and safe use of the product and all cleaning agents. The use of certain agents can be harmful to the surface appearance and lifespan of vinyl.
  • Page 22 • Follow proper procedures for effective uses of mops, cloths, and solutions. • Prepare cleaning solutions daily or as needed, and replace with fresh solution frequently according to facility policies and procedures. • Change the mop head at the beginning of each day and also as required by facility policy, or after cleaning up large spills of blood or other body substances.
  • Page 23: Disposal And Key To Symbols

    DISPOSAL AND KEY TO SYMBOLS DISPOSAL Lumex Recliner equipment and accessories can be disposed of. We recommend disassembling and dividing the equipment and components into different waste groups such as: metal, cable, electronic, recoverable resource and plastic for recycling or combustion.
  • Page 24: Key To Symbols

    KEY TO SYMBOLS The following symbols are used on Lumex Recliner product labels. MANUFACTURER GENERAL WARNING SIGN FRAGILE, HANDLE WITH CARE KEEP DRY ELECTRICAL AND ELECTRONIC CE MARK EQUIPMENT CAUTION CONSULT INSTRUCTIONS FOR USE EUROPEAN AUTHORIZED MEDICAL DEVICE REPRESENTATIVE UNIQUE DEVICE IDENTIFIER CE CERTIFICATION (SERIES FR587W ONLY) Info: CE Certification applies ONLY to Series FR587W Deluxe Clinical Care Recliner, Extra Wide.
  • Page 25: Technical Specifications

    TECHNICAL SPECIFICATIONS Series FR587W / FR587WH / FR587WHO Specification 50" (129.5 cm) Overall Height 33" (83.8 cm) Overall Width 36" (91.4 cm) Overall Depth 23" (58.4 cm) Width Between Arms " (67.3 cm) Arm Height from Floor 8" (20.3 cm) Arm Height from Seat "...
  • Page 26: Limited Warranty

    LIMITED WARRANTY SCOPE OF WARRANTY GF Health Products, Inc. (GF) warrants to the original purchaser only that it will replace or repair components, at GF’s sole discretion, that are defective in material or workmanship under normal use and service. All warranties are conditioned upon the proper use of the products strictly in accordance with good commercial practice and applicable GF instructions and manuals, including proper use and maintenance.
  • Page 27: Index

    INDEX Assembly 5 Operation 8 Cable tension, adjusting 13 Recliner operation 11 Care and maintenance 20 Caster, directional (swivel) 8 Side panel, install 10 Caster, locking 8 Side panel operation 10 Caster operation 8 Side panel, remove 10 CE Certification 24 Side table, lower 9 Side table operation 9 Disposal 23...
  • Page 28 Manufactured By: +1 770.368.4700 Information contained herein is subject to change without notice. GF Health Products, Inc. The most current and complete product information can be found on our website. One Graham-Field Way, Atlanta, GA 30340 www.grahamfield.com © 2012, GF Health Products, Inc. All Rights Reserved. LX_FR587W-INS-LAB-RevK22 Lumex is a registered trademark of GF Health Products, Inc.