Controls And Indicators; Inspections Prior To Starting; Starting And Stopping; Emergency Stopping - Nilfisk-Advance VHC110 Instructions For Use Manual

Hide thumbs Also See for VHC110:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
VHC110 - VHC120

Controls and indicators

1.
On/Off valve
2.
Pressure regulator
3.
Filter cleaning system

Inspections prior to starting

Before starting, check that:
The filters are installed.
The closing band is properly tightened.
The vacuum hose and tools have been correctly fitted into
the vacuum inlet (1).
In case of liquid application, the liquid mechanical stop is
properly installed inside the liquid container:
The bag or safety container is installed, if applicable.
Do not use the device if the filters are faulty.

Starting and stopping

Before starting the machine, lock the castor brakes
Open the valve (1) to start vacuuming.
Close the valve (1) to stop vacuuming.
Machines equipped with system for vacuuming
liquids
When the container is full, the liquid mechanical stop turns
off the vacuuming; the vacuum unit remains on.
Do not let the vacuum unit running, after the liquid stop
has been activated. Turn it off.

Emergency stopping

IT
Close the on/off valve. The machine stops.
GB
F
D
E
C447
Figure 5
Figure 6
CAUTION!
Figure 5
CAUTION!

Operation

Vacuum gauge (2): green zone (3), red zone (1)
When using the machine, check the flow control:
when the machine is operating, the pointer of the vacuum
gauge must remain in the green zone (3) to ensure that
the speed of the intake air does not drop below the safety
value of 20 m/sec;
If the pointer is in the red zone (1) it means that the speed
of the air in the vacuum hose is less than 20 m/s, and that
the machine is not operating in optimal conditions. Shake
or replace the filter.
during normal operation conditions, close the vacuum
hose, the pointer of the vacuum gauge must switch from
the green zone (3) to the red zone (1).
The air speed in the vacuum hose must not be less than
20 m/s.
Condition indicated by the vacuum gauge pointer in the
green zone (3).
All machines can be used only with hoses whose
diameters comply with the specifications in the
"Technical Data" table.
Consult the "Troubleshooting" chapter if faults occur.
At the end of a cleaning session
Close the on/off valve to stop vacuuming.
Wind up the connection cable.
Empty the container and clean the vacuum cleaner
as described in the "Maintenance, cleaning and
decontamination" paragraph.
Wash the container with clean water if aggressive
substances have been vacuumed.
Store the machine in a dry place, out of reach of
unauthorised people.
Lock the castor brakes.
During transport and when not using the machine, close
the vacuum inlet with the relevant plug (if equipped).
10
Figure 7
CAUTION!
CAUTION!
CAUTION!

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vhc120Vhc110 z1Vhc120 z155100224Vhc200

Table of Contents