PROBLEM
The charging base light
does not turn on when
the robot is out of the
charging base.
The charging base
indicator lights up
flashing slowly.
The charging base
indicator light flashes
rapidly.
The charging base
indicator lights up
flashing twice or three
times rapidly.
The charging base
indicator lights up
flashing twice or three
times rapidly.
The Warning icon lights
up on the keypad.
EN
CAUSES
The supply voltage is missing
or there is a fault in the charging
base.
The perimeter cable is not
connected or is broken.
The perimeter cable is too short
or there is a fault in the charging
base.
The charging base has detected
a short circuit on the charging
contacts.
The charging base has detected
a short circuit on the charging
contacts.
It indicates anomaly / failure
conditions.
SOLUTIONS
Check that the power supply unit is
plugged in correctly. Check the integrity of
the power supply connection cable.
Check the installation and repair the
break (See Par. 4.5.2).
Check that the length of the perimeter
cable is greater than indicated in
Par. 4.5.1. If necessary, install the resistor
(See Par. 4.5.4). If the problem persists,
contact a service centre.
Disconnect the charging base from the
mains, rectify any short circuits and clean
the charging contacts of the charging
base and the robot. Reconnect the
charging base to the mains. If the problem
persists, contact a service centre.
Disconnect the charging base from the
mains, rectify any short circuits and clean
the charging contacts of the charging
base and the robot. Reconnect the
charging base to the mains. If the problem
persists, contact a service centre.
See the app for more information or
contact a service centre.