Ex71
Drying NTC alarm
Ex72
Heaters NTC Alarm
Ex73
Steamer NTC Alarm
Ex83
Incorrect selector dial position
Ex86
Incorrect selector configuration
Self-diagnosis of main circuit board
Ex87
faulty
User interface board communication
Ex91
alarm
Inconsistent user interface board
Ex92
protocol
Ex93
MCF checksum alarm
Ex94
CCF checksum alarm
Technical Support - A.D.L.
Full name
 The cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 Stops cycle execution
 Stops cycle execution
 No action.
 No action.
 No action.
 No action possible.
 No action possible.
 The machine could not work until a right
configuration file is programmed.
 The machine could not work until a right
configuration file is programmed.
Action
73/76
599 74 12-74 Rev.01
Notes and possible causes
NTC1 reading out of range.
 Wiring failure.
 NTC failure.
 NTC reading circuit error (main board error).
NTC2 reading out of Range
 Wiring Failure
 NTC Failure
 NTC reading circuit Failure (Main Board Failure)
NTC3 reading out of Range
 Wiring Failure
 NTC Failure
 NTC reading circuit Failure (Main Board Failure)
 The code for the selector position is not
recognised.
 Selector faulty (main board error).
 Incorrect selector configuration (main board
failure).
 Selector faulty (main board error).
 Main board faulty.
 Faulty wiring.
 User interface board faulty.
 Main board faulty.
 The user interface board is not compatible
with the main board.
 Wrong machine configuration file.
 Wrong cycle configuration file.