Water conductivity
The conductivity of the water used to wash the laundry varies from area to area; the conductivity sensor
is set to a standard level, significant variations in conductivity level may have a negative effect on the
final results of drying (laundry that is either too dry or still damp).
These variations can be noted particularly in "slightly damp" and "ready-to-iron" cycles; "wardrobe dry"
cycles are practically never influenced by changes in conductivity.
To adjust the conductivity level, turn on the tumble dryer at the On/Off button and press the Drying and
Spin speed buttons simultaneously.
To change the conductivity value according to the table, press the Start/Pause button.
LCD
The normal factory setting is medium level, but some models may have a different configuration.
Ask your local water supplier for details of the conductivity level of your water supply.
Technical Support - A.D.L.
Conductivity level
LOW
MEDIUM
HIGH
42/76
Approximate value (
µ
< 300
300 – 600
> 600
599 74 12-74 Rev.01