Position 10
Last alarm display and
possible reset
Position 11 and subsequent positions
Last alarm display and
possible reset
Technical Support - A.D.L.
Purpose of the test:
Behaviour:
Working conditions:
Behaviour:
Working conditions:
66/76
To see the alarm and delete it.
The LCD display flashes and shows any
alarm present.
Turn the dial to position 10, paying attention not
to stop in position 8 in order to avoid error 32.
Press the Start/Pause button to see all the
alarms present.
To delete the alarms, hold down the Start/Pause
buttons and press the button on the left.
All LEDs flash in sequence.
Press a button and the corresponding LED is lit;
the code is shown on the LCD display and the
buzzer sounds.
door closed (timeout 10 secs.).