mi PC CARD DIAGNOSIS
Make sure that connecting cables, connectors and AC adapter are
No.
Symptom
Troubleshooting procedures
Source of problem | Ref.Page
No. |
| Result |
1
|Cannot insert PC CARD.
¥ Cannot remove PC
is the PC CARD deformed?
=
= a
Slot
| 73 |
CARD.
Le
:
YES
|Go to No. 2-2.
E
2
properly.
Is a correct driver used?
Diner canware
|
2 Is there a conflict in
YES
|Configuration
configuration? (I/O Address, IRQ) | NO
|Go to No. 2-3
mi STATUS LCD DIAGNOSIS
Make sure that connecting cables, connectors and AC adapter are
No.
Symptom
Troubleshooting procedures
Source of problem | Ref.Page
No. |
| Result |
;
Indicator is not displayed
Replace the STATUS LCD.
STATUS LCD.
4-1
'
Main P.C.B. or LCD
7-10,7-12
properly.
Does operation return to normal?
EPC
Make sure that connecting cables, connectors and AC adapter are
not loose or disconnected prior to testing.
Data cannot be sent or
4-1 Is the Infrared Communication
YES
|Go to No. 1-2.
| ——— |
received.
Port enabled in Setup?
| NO {Improper setting.
==
Is the same transmission protocol yes |
1-2 |set for both the sending and
SES = < aa
receiving units?
asa
pier
g.
CF-62
|
not loose or disconnected prior to testing.
7-3
7-9
2
|PC CARD does not work
2-3 Does Diagnostic Test report
YES
|Main P.C.B.
7-10
problem in PC CARD controller?
| NO
|PC CARD
7-3
not loose or disconnected prior to testing.
MZ INFRARED COMMUNICATION
PORT DIAGNOSIS
Troubleshooting procedures
Source of problem | Ref.Page
No. |
| Result |
4-3 Does Diagnostic Test report
YES
|Main P.C.B
problem?
NO
{Power P.C.B