Grundfos SCALA Series Installation And Operating Instructions Manual

Grundfos SCALA Series Installation And Operating Instructions Manual

Advertisement

http://waterheatertimer.org/Water-heater-recirculation-system.html
GRUNDFOS INSTRUCTIONS
SCALA
Installation and operating instructions

Advertisement

Table of Contents
loading

Summary of Contents for Grundfos SCALA Series

  • Page 1 GRUNDFOS INSTRUCTIONS SCALA Installation and operating instructions...
  • Page 2: Table Of Contents

    English (GB) Installation and operating instructions Original installation and operating instructions Read this document and the quick guide before These installation and operating instructions describe Grundfos installing the product. Installation and operation must SCALA2 domestic water supply pumps. comply with local regulations and accepted codes of Sections 1-5 give the information necessary to be able to unpack, good practice.
  • Page 3: Notes

    1.3 Notes 3.2 System sizing The symbols and notes below may appear in Grundfos installation and operating instructions, safety instructions and Make sure that the system in which the pump is service instructions. incorporated is designed for the maximum pump pressure.
  • Page 4 3.3.3 Connecting the piping system Pipe hanger for rigid pipe Make sure that the pump is not stressed by the Flexible hose piping system. Always loosen and tighten the union nuts on the inlet and outlet ports by hand. Damage to the inlet and Rubber pad outlet parts increases the risk of leakage.
  • Page 5 3.3.7 Suction from a well Pos. Description Foot valve with strainer (recommended) Minimum 1 ° inclination 3.3.9 Inlet pipe length The overview below shows the different possible inlet pipe lengths, depending on the vertical pipe length. The overview is only intended as a guide. Fig.
  • Page 6: Electrical Connection

    3.4 Electrical connection 4. Starting up the product Carry out the electrical connection according to local regulations. Do not start the pump until it has been filled with Check that the supply voltage and frequency liquid. correspond to the values stated on the nameplate. DANGER 4.1 Priming the pump Electric shock...
  • Page 7: How To Set The Correct Pressure

    The pressure settings 4.5, 5.0 and 5.5 bar (65, 73 and 80 psi) require a positive inlet pressure and these settings must only be used when boosting from the water mains. Fig. 12 Grundfos SCALA2 pump Pos. Description Air valve for built-in pressure tank Operating panel.
  • Page 8: Intended Use

    6.2 Intended use 6.4.2 Type key This pump has been evaluated for use with water SCALA2 3 -45 A K C H D only. Type range Only use SCALA2 pumps according to the SCALA2 specifications stated in these installation and operating instructions.
  • Page 9: Control Functions

    7. Control functions Water colum 7.1 Menu overview, SCALA2 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 Fig. 16 Pressure indication table 7.1.2 Indicator lights for SCALA2 Indications Description Operating indications The operating panel is locked. Fig. 14 SCALA2 operating panel Power supply failure SCALA2 Function On/off...
  • Page 10: Setting The Product

    8. Setting the product 8.3.2 Self-learning function The factory setting for this function is "on". The pump will remember the controller settings even if it is turned off. If the pump cannot reach the user-defined pressure setpoint, the 8.1 Setting the outlet pressure self-learning function will automatically adjust the setpoint.
  • Page 11: Resetting To Factory Settings

    8.3.3 Auto reset 9. Servicing the product The factory setting for this function is "on". DANGER Electric shock This function allows the pump to automatically check if the Death or serious personal injury operating conditions are back to normal. If the operating - Before starting any work on the product, make conditions are back to normal, the alarm indication will be reset sure that the power supply has been switched off...
  • Page 12: Customer Service Information

    9.2 Customer service information 2. Disconnect the power supply. 3. Open a tap to release the pressure in the pipe system. For further information on service parts, see Grundfos Product Center on www.product-selection.grundfos.com. 4. Close the isolating valves and/or drain the pipes.
  • Page 13: Fault Finding The Product

    12. Fault finding the product 12.1 Grundfos Eye operating indications Grundfos Eye Indication Description The power is off. No lights are on. The pump is not running. Two opposite green indicator lights running in the The power is on. direction of rotation of the pump.
  • Page 14: Fault Finding Chart

    The pump is blocked by See section 10. Starting up the product impurities. after standstill. Contact Grundfos Service if the problem persists. e) Dry running. Check the water source, and prime the pump. The maximum runtime has been Check the installation for leakage and exceeded.
  • Page 15 Fault Cause Remedy 4. System a) The setpoint is set too high. The Reduce the pressure to a new setpoint overpressure. difference between the outlet (maximum 3.5 bar (51 psi) + positive pressure and the inlet pressure inlet pressure). must not exceed 3.5 bar (51 psi). Example: If the inlet pressure is 0.5 bar (7 psi), the maximum outlet pressure is 4 bar (58 psi).
  • Page 16: Technical Data

    Pipe connections are R 1" or NPT 1". 1. Use the public or private waste collection service. 13.3 Electrical data 2. If this is not possible, contact the nearest Grundfos company or service workshop. Stand-by See also end-of-life information on...
  • Page 17 Unit 1, Ground floor Turkey Av. Humberto de Alencar Castelo Branco, Siu Wai Industrial Centre GRUNDFOS Pumper A/S GRUNDFOS POMPA San. ve Tic. Ltd. Sti. 29-33 Wing Hong Street & Strømsveien 344 Gebze Organize Sanayi Bölgesi CEP 09850 - 300...
  • Page 18 98880508 1217 ECM: 1218564 www.grundfos.com...