14. Fault finding

DANGER
Electric shock
Death or serious personal injury
Before starting any work on the
product, make sure that the power
supply has been switched off and that
it cannot be accidentally switched on.

14.1 Grundfos Eye operating indications

Grundfos Eye

14.2 Fault resetting

You can reset a fault indication in one of the following
ways:
When you have eliminated the fault cause, reset
the pump manually by pressing the Reset button.
The pump will then revert to normal duty.
If the fault disappears by itself, the pump will
attempt to reset automatically and the fault
indication will disappear if automatic reset is
successful and provided that you have enabled
the auto reset function in the service menu.
26
Indication
No lights are on.
Two opposite green indicator lights running in the
direction of rotation of the pump.
Two opposite green indicator lights are permanently
on.
Two opposite red indicator lights are flashing
simultaneously.
Two opposite red indicator lights are flashing three to
five times and in between two opposite green indicator
lights are flashing one time.
Description
Power off
The pump is not running.
Power on
The pump is running.
Power on
The pump is not running.
Alarm
The pump has stopped.
Alarm
The pump has stopped.
Contact Grundfos.