Fault
Protective
function
Alarm,
Warning, Error
message
Surrounding air temperature
Surrounding air humidity
Storage temperature
Ambience
Altitude/vibration
*1
Not activated in the inverter in the initial state.
*2
Applicable to conditions for a short time, for example, in transit.
*3
For the installation at an altitude above 1000 m, consider a 3% reduction in the rated current per 500 m increase in altitude.
92
4. Specifications
4.3 Common specifications
Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during
deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip
during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload
trip (electronic thermal relay function), Motor overload trip (electronic thermal relay function), Heat
sink overheat, Undervoltage, Input phase loss, Stall prevention stop, Loss of synchronism detection
Upper limit fault detection, Lower limit fault detection, Output side earth (ground) fault overcurrent,
Output short circuit, Output phase loss, External thermal relay operation, PTC thermistor operation
Parameter storage device fault, Retry count excess, CPU fault, Abnormal output current detection,
Inrush current limit circuit fault, USB communication fault, Analog input fault, Overspeed
*1
occurrence
, Speed deviation excess detection
*1
Acceleration error
definition error by the PLC function, Board combination fault
Fan alarm, stall prevention (overcurrent), stall prevention (overvoltage), regenerative brake pre-
*1
alarm
, electronic thermal relay function pre-alarm, PU stop, maintenance timer alarm, parameter
write error, operation panel lock
home position return setting error
emergency drive in operation, incorrect parameter setting
-20°C to +50°C
95% RH or less (non-condensing)
*2
-40°C to +70°C
Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)
*3
Maximum 3000 m
*1
, PID signal fault, Opposite rotation deceleration fault
*1
, Password locked, speed limit indication
*1
, home position return uncompleted
2
, 5.9 m/s
or less at 10 to 55 Hz in X, Y, and Z directions
*1
, Excessive position fault
, Brake sequence fault
*1
, Internal circuit fault, User
*1
, stroke limit warning
*1
, load fault warning,
*1
,
*1
,
*1
,
*1
,