 Reinstallation of the wiring cover 2
• FR-E820-0340(11K) or lower, FR-E840-0196(11K) or lower, and FR-E820S-0082(2.2K) or lower
(a)
Sheets
Sheets
(a)
When reinstalling the wiring cover 2, the sheets should be placed inside the cover.
(b)
Tighten the mounting screws of the wiring cover 2.
(The tightening torque is 0.9 to 1.3 N·m for the FR-E820-0167(5.5K) or lower, FR-E840-0094(5.5K) or lower, and FR-E820S-0082(2.2K)
or lower,
1.4 to 1.9 N·m for the FR-E840-0149(7.5K) and FR-E840-0196(11K),
or 2.8 to 3.6 N·m for the FR-E820-0255(7.5K) and FR-E820-0340(11K).)
• FR-E820-0476(15K) or higher, FR-E840-0298(15K) or higher
(a)
Tighten
Tighten
Tighten
(a)
Tighten the mounting screws of the wiring cover 2.
(The tightening torque is 1.4 to 1.9 N·m for the FR-E840-0298(15K),
2.8 to 3.6 N·m for the FR-E820-0476(15K), FR-E820-0587(18.5K), and FR-E840-0349(18.5K),
or 4.7 to 6.4 N·m for the FR-E820-0748(22K) and FR-E840-0383(22K) or higher.)