4.
Always use conduit hubs to connect conduits to the knockout holes. The hubs shall be assembled to the conduits
before they are installed in the knockout holes.
Inverter capacity
FR-E820-0011(0.2K), 0017(0.4K)
FR-E820S-0011(0.2K)
FR-E820-0030(0.75K), 0051(1.1K)
FR-E820S-0017(0.4K)
FR-E820-0082(2.2K), 0102(3.0K)
FR-E840-0018(0.75K) to 0047(2.2K)
FR-E820S-0030(0.75K)
FR-E820S-0051(1.1K)
FR-E820-0167(5.5K)
FR-E840-0059(3.0K), 0094(5.5K)
FR-E820S-0082(2.2K)
FR-E840-0149(7.5K), 0196(11K)
FR-E820-0255(7.5K) to 0587(18.5K)
FR-E840-0298(15K), 0349(18.5K)
Handling of the wiring cover (FR-E820-0748(22K) or higher, FR-E840-0383(22K) or higher)
1.
To prevent injury, wear protective equipment such as cut-resistant gloves.
2.
Place the wiring cover 2 securely on wooden blocks or the like to punch out knockout holes easily.
3.
To punch out the knockout holes in the wiring cover 2, use a go-through screwdriver and alternately tap the points
marked with black circles in the following figure repeatedly. Tilt the screwdriver when tapping the points as the wiring
cover 2 has metal sheets. Be careful not to put the screwdriver directly on the joints. Remove any sharp edges and
burrs from the knockout holes.
(Example) FR-E820-0748(22K)-HVC
44
2. Installation and Wiring
2.5 Main circuit terminals
Number of holes
For main circuit
2
1 (Hole size: 17.5 × 52)
3
1 (Hole size: 17.5 × 52)
3
1 (Hole size: 60 × 17.5)
3
1 (Hole size: 17.5 × 60)
3
1 (Hole size: 17.5 × 60)
3
1 (Hole size: 20 × 60)
3
1 (Hole size: 20 × 60)
Hole diameter for main circuit
For control circuit
22.5
22.5
28.1
28.1
35.3
35.3
44.9
Go-through
screwdriver
(mm)
ジョイント
Joints