Mitsubishi Electric FR-E800-HVC Series Instruction Manual page 87

Table of Contents

Advertisement

 Single-phase 200 V power supply
Model FR-E820S-[]-HVC
Applicable motor capacity
LD
*1
(kW)
Rated capacity
LD
*2
(kVA)
*3
LD
Rated current (A)
Overload current
LD
*4
rating
*5
Voltage
Rated input AC (DC) voltage/frequency
Permissible AC (DC) voltage fluctuation
Permissible frequency fluctuation
Rated input current
Without DC reactor
*7
(A)
With DC reactor
Power supply capacity
Without DC reactor
*6
(kVA)
With DC reactor
Protective structure (UL 50)
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi Electric standard 4-pole motor.
*2
The rated output capacity is the value with respect to 230 V output voltage.
*3
The following table shows the current value initially set in Pr.9 Electronic thermal O/L relay, Pr.56 Current monitoring reference, and Pr.557
Current average value monitor signal output reference current. The value in the table is also used as the reference current value (100%
value) for Pr.22 Stall prevention operation level (Torque limit level), Pr.150 Output current detection level, Pr.165 Stall prevention
operation level for restart, and Pr.874 OLT level setting.
Model FR-E820S-[]-HVC
Current value (A)
*4
The percentage of the overload current rating is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow
time for the inverter and motor to return to or below the temperatures under 100% load. For single-phase power input model, the bus voltage
decreases to power failure detection level and the load of 100% or higher may not be available if the automatic restart after instantaneous power
failure function (Pr.57) or the power failure stop function (Pr.261) is set and power supply voltage is low while the load increases.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
The maximum point of the voltage waveform at the output side of the inverter is approximately the power supply voltage multiplied by
*6
The power supply capacity varies with the value of the input power impedance (including those of the input reactor and cables).
*7
The rated input current is the value at a rated output voltage. The input power impedances (including those of the input reactor and cables) affect
the value.
*8
The structure is suitable for Installation in a Compartment Handling Conditioned Air (Plenum).
86
4. Specifications
4.1 Inverter rating
0011
0017
0030
0.2
0.4
0.75
0.4
0.7
1.2
1.1
1.7
3.0
120% 60 s, 150% 3 s (inverse-time
characteristics) at surrounding air
temperature of 50°C
Three-phase 200 to 240 V
Single-phase 200 to 240 V, 50/60 Hz
170 to 264 V, 50/60 Hz
±5%
LD
3
4.5
6.7
LD
1.8
2.8
5.0
LD
0.9
1.7
2.5
LD
0.6
1.1
1.9
UL Type 1 (Enclosed Type
Natural
0.8
1.1
1.9
0011
0017
0030
0051
1.3
2.0
3.5
6.0
0051
0082
1.1
2.2
2.0
3.3
5.1
8.2
11.4
18.6
9.1
14.7
3.9
5.5
3.0
4.2
*8
)
Forced air
2.0
2.3
0082
9.6
2
.