NOTE : UNIT IS ADJUSTABLE
Keep in mind that the hooks on the mounting plate are smaller than the holes on the back of the unit.
If you find that you don't have ample room to connect embedded pipes to the indoor unit, the unit
can be adjusted left or right by about 30-50mm (1.18-1.96in), depending on the model.
(1-3/16~2in)
CAUTION
For the units adopt the following pipe connectors, please strictly perform the
piping work in accordance with the following instructions.
Connector A
Connector B
Cross-shape
part
If refrigerant piping is already embedded in the wall,
do the following:
Hook the top of the indoor unit on the upper hook of the
●
mounting plate.
Use a bracket or wedge to prop up the unit, giving you
●
enough room to connect the refrigerant piping, signal cable,
and drain hose.
Connect drain hose and refrigerant piping (refer to
●
Refrigerant Piping Connection section of this manual for
Wedge
instructions).
Keep pipe connection point exposed to perform the leak
●
test (refer to Electrical Checks and Leak Checks section of
this manual).
After the leak test, wrap the connection point with
●
insulation tape.
Remove the bracket or wedge that is propping up the unit.
●
Using even pressure, push down on the bottom half of the
●
unit. Keep pushing down until the unit snaps onto the hooks
along the bottom of the mounting plate.
30-50mm
Move to left or right
Red point
protruding
30-50mm
(1-3/16~2in)
Before performing the refrigerant piping
●
connection, always wear work gloves and
goggles, and remember that the connectors
A and B are not allowed to face people directly.
Keep pressing the cross-shape part of connector
●
B with a tool for about 5~10 seconds until the
red protuding point of connector A retracts
completely.
Remove connectors A and B, then perform
●
the refrigerant piping connection between
indoor unit and outdoor unit.
19 19