Trigger Height Adjustment
Follow this procedure to ensure the gun triggers
properly during a purge.
1. Insert the gun into the Gun Flush Box.
NOTE: If using a Pro Xp
must be rotated to clear the hinge spring during insertion
and removal.
2. Remove the four screws that hold the cover (K) to
the Gun Flush Box. See Fig. 8.
3. Force the cylinder triggers on by connecting air to
port C (J). See Fig. 8. Turn on the air to extend both
cylinders.
4. Loosen both screws (L) on the side of the box that
hold the cylinder block (M). See Fig. 9.
J
Fig. 8 ______________________________________
10 309227H
™
Smart Gun model, the gun
K
5. Raise the cylinder (M) until the pin (N) opens the
trigger fully. See Fig. 9.
6. Tighten both screws (L) at the desired location for
the cylinder block (M).
L
M
Fig. 9
_____________________________________
N