Adam Equipment GBK Series Manual

Adam Equipment GBK Series Manual

Hide thumbs Also See for GBK Series:

Advertisement

This document hosted by: www.oldwillknottscales.com
Adam Equipment
GBK and GFK Series
P.N. 3056610542, Revision D, August 2011)
(
Software Rev.
V1.21 GK-H scales for Europe
V2.29 EC Approved scale
V3.41 GK scale for Europe
V4.12 GK-H scale for USA
V5.41 GK scales for USA
© Adam Equipment Company 2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GBK Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Adam Equipment GBK Series

  • Page 1 GBK and GFK Series P.N. 3056610542, Revision D, August 2011) Software Rev. V1.21 GK-H scales for Europe V2.29 EC Approved scale V3.41 GK scale for Europe V4.12 GK-H scale for USA V5.41 GK scales for USA © Adam Equipment Company 2011...
  • Page 2 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase: Name of the supplier and place: © Adam Equipment Company 2011...
  • Page 3: Table Of Contents

    SERVICE PARAMETERS ..............54 15.1. ACCESS TO PARAMETERS ................54 15.2. USING “1000” TO ENTER THE SERVICE PARAMETERS ......55 REPLACEMENT PARTS AND ACCESSORIES........ 60 SERVICE INFORMATION..............61 WARRANTY INFORMATION............. 62 APPENDIX ..................63 1 | page © Adam Equipment Company 2011...
  • Page 4 2 | page © Adam Equipment Company 2011...
  • Page 5: Introduction

    • OIML Approved models, GBK/GFK-M, do not allow pounds units, have calibration controlled by jumpers or passcodes and other limitations as noted in the manual. 3 | page © Adam Equipment Company 2011...
  • Page 6: Specifications

    (w x d x h) Net Weight 7.4kg / 16.3 Lb 7.4kg / 16.3 Lb 7.4kg / 16.3 Lb 7.4kg / 16.3 Lb 7.4kg / 16.3 Lb Features Weighing/Counting/Checkweighing with LED lights/Percentage/Hold function/RS232 P a g e © Adam Equipment Company 2011...
  • Page 7 12.5kg / 27.6 Lb 12.5kg / 27.6 Lb 12.5kg / 27.6 Lb 25.5 kg / 56.2 Lb 12.5kg / 27.6 Lb 12.5kg / 27.6 Lb Features Weighing/Counting/Checkweighing with LED lights/Percentage/Hold function/RS232 P a g e © Adam Equipment Company 2011...
  • Page 8 300mm x 400mm x 50mm / 11.8” x 15.5” x 2” Overal Dimensions 300mm x 520mm x 660mm / 11.8” x 20.5” x 26” (w x d x h) 7.4kg / 16.3 Lb Net Weight Weighing/Counting/Checkweighing with LED lights/Percentage/Hold function/RS232 Features P a g e © Adam Equipment Company 2011...
  • Page 9 Overal Dimensions 400 mm x 620 mm x 860 mm (w x d x h) 15.7” x 24.4” x 33.8” 12.5kg / 27.6 Lb Net Weight Weighing/Counting/Checkweighing with lights/Percentage/Hold Features function/RS232 P a g e © Adam Equipment Company 2011...
  • Page 10 © Adam Equipment Company 2011 P a g e...
  • Page 11: Installation

    Avoid air movement such as from fans or opening doors. Do not place near open windows or air-conditioning vents. • Keep the scales clean. Do not stack material on the scales when they are not in use. © Adam Equipment Company 2011 P a g e...
  • Page 12: Setting Up The Scales

    Counter has been enabled (see section 6) the current values will be displayed. These values should match the values marked on the scale at the time of verification, if it has been verified. © Adam Equipment Company 2011 P a g e...
  • Page 13: Keypad

    This is used to select the weighing units Allows the weight, unit weight, and from a preset list of available units. count to be seen when parts counting or to change from weight to % in percent weighing © Adam Equipment Company 2011 P a g e...
  • Page 14 [1] to [0] Allow entering numerical values where and [CE] required, setting of limits, tare value, time and date for example. © Adam Equipment Company 2011 P a g e...
  • Page 15: Display

    The scale is in Parts counting mode The scale is in Check weighing mode HI, OK, LO The colons “:” are used to separate pounds from ounces and for the real time clock. © Adam Equipment Company 2011 P a g e...
  • Page 16: Calibration Counter For Approved Scales

    In this way if the record of the Calibration or Parameter counters do not agree with recorded settings the responsible person inspecting the scale can take appropriate action. © Adam Equipment Company 2011 P a g e...
  • Page 17 (see section 15.2). “F4 Int” Initial Zero Range “F5 rEZ” Re-Zero range “F6 SCS” Successive Tare Enable “F7 Cnt” Display ADC counts “F8 Zem” Zero Mode “F9 Lvd” Low voltage detection © Adam Equipment Company 2011 P a g e...
  • Page 18: Battery

    The auto power off can be set by the user to disable the feature or to a pre-set time interval. See setting of the parameter “S3 AoF “ in section 13.3. © Adam Equipment Company 2011 P a g e...
  • Page 19: Operation

    • As a product is added only the weight of the product will be shown. The scale could be tared a second time if another type of product was to be © Adam Equipment Company 2011 P a g e...
  • Page 20: Preset Tare (Not Available On Approved Scales)

    • Press [Tare] to tare the scale. The value that was entered is stored as the tare value and it is subtracted from the display, leaving a negative number on the display. © Adam Equipment Company 2011 P a g e...
  • Page 21: Weighing

    • If a container is to be used, place this container on the platform before entering parts counting and press [Tare]. • Press [Cnt] to enter the Parts Counting mode. The display will show the last sample size used. For example, “10 Pcs”. © Adam Equipment Company 2011 P a g e...
  • Page 22 10.2.2. • During parts counting the display can be changed to show the net weight, unit weight and number of parts by each time pressing the [Func] key. © Adam Equipment Company 2011 P a g e...
  • Page 23 Either use this sample size with a different part or enter a new sample size as above. • To return to weighing, press [Unit] when “XX pcs” is displayed. © Adam Equipment Company 2011 P a g e...
  • Page 24: Check-Weighing

    3. If Limit Password is enabled then enter the password which will allow you to change the limits or the operation of the beeper or bargraph. © Adam Equipment Company 2011 P a g e...
  • Page 25: Setting Up While Weighing

    • Pressing the [Tare] key to enter the value will return the scale to weighing, with the Check-weighing function enabled. © Adam Equipment Company 2011 P a g e...
  • Page 26: Setting Up While Parts Counting Or % Weighing

    (including pcs for parts counting and % for percent weighing) as well as settings for the beeper and bar graph. During Check weighing the current limits can be stored or previously stored units can be recalled. © Adam Equipment Company 2011 P a g e...
  • Page 27 X” will be displayed for 2 seconds indicating the values stored in the location “X” is being recalled. The scale will change to the recalled limits, weighing units and settings for the beeper and bar graph. © Adam Equipment Company 2011 P a g e...
  • Page 28: Percent Weighing

    • Press [Func]. The first option is “FUnC 1”, press the [Func] key 3 more times to display “FUnC 4”. • Press the [Tare] key. “F4 PCt” will be displayed. © Adam Equipment Company 2011 P a g e...
  • Page 29 100%. When “F4 PCT” is displayed, enter the weight to be used for the 100% reference, then press [Tare] to accept the reference weight. The display will show “0.00 %”. © Adam Equipment Company 2011 P a g e...
  • Page 30 The display may jump by large numbers unexpectedly if small weights are used to set as 100% reference. The scale checks if the weight is too small and will show Error 7. © Adam Equipment Company 2011 P a g e...
  • Page 31: Animal (Dynamic) Weighing

    To increment the value shown press the [Func] key then press the [Tare] key to accept it. • The display will flash “Ani “ 2 times then show the current weight, 0.00. The scale is now ready to weigh. © Adam Equipment Company 2011 P a g e...
  • Page 32: Animal Weighing Procedure

    • The scale will remain in the animal weighing mode until the [Zero] key is pressed. Then it will return to normal weighing. © Adam Equipment Company 2011 P a g e...
  • Page 33: Accumulated Total

    "ACC 1" and then the weight in memory for 2 seconds before returning to normal. The weight can be output to a printer or PC using the RS-232 interface. © Adam Equipment Company 2011 P a g e...
  • Page 34 • To print the total, press [Print] to recall and then immediately press [Print] the second time to print the results. • To erase the memory, press [Print] to view the total and then immediately press [CE] to clear the memory. © Adam Equipment Company 2011 P a g e...
  • Page 35: Automatic Accumulation

    3. More products can be added and [Print] be pressed again for up to 99 entries until the capacity of display is exceeded. © Adam Equipment Company 2011 P a g e...
  • Page 36: Rs-232 Specification

    Pin 3 Output Pin 2 Input Pin 5 Signal Ground The scale can be set to print text in English, French, German or Spanish. See the RS- 232 parameters section for details. © Adam Equipment Company 2011 P a g e...
  • Page 37 User ID 234567 <cr><lf> <cr><lf> Net Wt. (or Gross Wt.) Net Wt 1.234 kg <cr><lf> <cr><lf> <cr><lf> <cr><lf> <cr><lf> Data Format-Parts Counting Output: Weight, Unit weight and number of parts are printed. © Adam Equipment Company 2011 P a g e...
  • Page 38 User ID 234567 <cr><lf> <cr><lf> Net Wt. (or Gross Wt.) Net Wt. 1.234 kg <cr><lf> for metric and lb for pounds Unit Wt. 123 g <cr><lf> g 10 pcs <cr><lf> <cr><lf> <cr><lf> © Adam Equipment Company 2011 P a g e...
  • Page 39 Data Format- Continuous Output- Parts Counting: Net Weight (or Gross wt.) 1.234 kg <cr><lf> Kg and g for metric and Lb for pounds U.W. 123 g <cr><lf> 10 pcs <cr><lf> <cr><lf> <cr><lf> © Adam Equipment Company 2011 P a g e...
  • Page 40 3. In other languages the format is the same but the text will be in the language selected. 4. When the scale is in the Lb:oz weighing unit the RS-232 output will only show pounds. 10lb:8oz will be printed as 10.5 lb. © Adam Equipment Company 2011 P a g e...
  • Page 41 Fecha Print date Time Heure Zeit Hora Print time Scale ID Bal ID Waagen ID Bal ID Scale ID number User ID Util ID Nutzer ID Usuario ID User ID Number © Adam Equipment Company 2011 P a g e...
  • Page 42: Input Commands Format

    P<cr><lf> Prints the results to a PC or printer using the RS-232 interface. It also adds the value to the accumulation memory if the accumulation function is not set to automatic. © Adam Equipment Company 2011 P a g e...
  • Page 43: Calibration

    (if entered directly). Remove the calibration mass. • If an error message “FAIL H” or “FAIL L” is shown, re-check the calibration and repeat. If the error cannot be corrected contact your supplier. © Adam Equipment Company 2011 P a g e...
  • Page 44: Parameter Settings

    The display will go directly to “FUnC 1”. • Press [Tare] to enter the group. • Press [Func] to scroll through the parameters and press [Tare] to enter a parameter setting. © Adam Equipment Company 2011 P a g e...
  • Page 45 Limit Lock. time. With LLK set to Preset (PSt), the user is allowed to use one of the preset limits only. © Adam Equipment Company 2011 P a g e...
  • Page 46 The Check weighing password is separate from the scale password, see section 13.3. If the password is other than 0000, user must enter the password to gain access to “F3 LLk”, “F4 LEd”, “F5 bEP”, “F6 CPS” and “F7 nCK”. © Adam Equipment Company 2011 P a g e...
  • Page 47: Rs-232 Parameters

    Description Options Default Values or setting C1 on Enable or disable the RS- Prt on Prt on 232 interface Prt oFF C2 bd Baud Rate 9600 1200 2400 4800 9600 19200 © Adam Equipment Company 2011 P a g e...
  • Page 48 Set Scale ID To be entered manually 000000 C8 Lab Lab On Lab On Set the print format to be a label as shown (ON) or a Lab Off single line (Off) © Adam Equipment Company 2011 P a g e...
  • Page 49 Do not accumulate. If the [Print] key is pressed approved indicators at any time the scale is stable print only. Accumulation will only occur if scale returns to zero first. © Adam Equipment Company 2011 P a g e...
  • Page 50 On EC approved scales printing is not allowed less than 20 divisions. Accumulation is only allowed if the weight is greater than 20 divisions. © Adam Equipment Company 2011 P a g e...
  • Page 51: Scale Parameters

    S2 bL EL oFF EL AU Backlight set to always on, always off or automatic on EL on whenever a weight is EL AU placed or a key is pressed © Adam Equipment Company 2011 P a g e...
  • Page 52 Must be entered twice when asked. When complete, it will display “donE”. S8 CAL Calibration Calibrate the scale. See Section 10.0 © Adam Equipment Company 2011 P a g e...
  • Page 53: Percent Weighing And Animal Weighing

    This parameter allows the None Enabled user to enter the Percent always weighing Function. Section 10.7. F4 AnL Enter the Animal Weighing Enabled Set the filter value. mode of operation, See Always section 10.8 © Adam Equipment Company 2011 P a g e...
  • Page 54: Error Messages

    Err 8 High limit input error Low limit is set first, then the high limit is set lower than the low limit and high limit not equal to zero. © Adam Equipment Company 2011 P a g e...
  • Page 55 FAIL H or Calibration error Improper calibration (should be within +10% factory FAIL L calibration). The old calibration data will be retained until the calibration process is complete. © Adam Equipment Company 2011 P a g e...
  • Page 56: Service Parameters

    Empty the platform by removing the load, if “UnLoAd ” there is any and press [Tare] Load the requested calibration weight and press “LoAd” “6” “KiLoS” [Tare] If Calibration is complete, “SPAn PASS” will be “SPAn” “PASS” © Adam Equipment Company 2011 P a g e...
  • Page 57: Using "1000" To Enter The Service Parameters

    For the non approved indicator press the [Tare] key during the display counting when turned on, Approved Indicators: For the Approved version a jumper can be installed to allow access or the Calibration and Parameter Counters must be enabled (see 15.2.10). © Adam Equipment Company 2011 P a g e...
  • Page 58 Successive Tare Enable “F7 Cnt” Display the A/D counts “F8 Zem” Zero Mode “F9 Lvd” Low voltage detection “F10 Cn” GK-M only, Calibration and Parameter counters or “F10 Az” Auto Zero Range © Adam Equipment Company 2011 P a g e...
  • Page 59 Press the [Tare] key to return to the PARAMETER menu. Press the [Zero] key to return to weighing. Typical value at zero is 30,000-90,000 (approx.) Typical value at full capacity is 500,000 (approx.) © Adam Equipment Company 2011 P a g e...
  • Page 60 1-2 of J1, See section 15.2. Press the [Func] key to change the value. Press [Tare] to accept the displayed value. Press [Zero] to return to weighing. © Adam Equipment Company 2011 P a g e...
  • Page 61 The display will show the current setting, 0.5d, 1d, 2d, or 5d. Press the [Func] key to change the value. Press [Tare] to accept the displayed value. Press [Zero] to return to weighing. © Adam Equipment Company 2011 P a g e...
  • Page 62: Replacement Parts And Accessories

    Equipment. A partial list of such items is as follows- • Main Power cord or adaptor for • Stainless Steel Pan • In use cover USA versions. • Replacement Battery • Printer, etc. © Adam Equipment Company 2011 P a g e...
  • Page 63: Service Information

    Include any recent history of the unit. For example: -Has it been working since it’s delivered -Has it been in contact with water -Damaged from a fire -Electrical Storms in the area -Dropped on the floor, etc. © Adam Equipment Company 2011 P a g e...
  • Page 64: Warranty Information

    WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company.
  • Page 65: 19. Appendix

    Enter using numeric keys S7 SPS Enter using numeric weighing User ID Scale password keys C7 Sid Enter using numeric keys S8 CAL Perform calibration Scale ID C8 LAb LAb On Lab Off P a g e © Adam Equipment Company 2011...
  • Page 66 Signature Date Unterschrift Datum Signature Date 22 July 2011 Handtekening Datum J.S. Cumbach Firma Date Firma Fache Technical Manager P a g e © Adam Equipment Company 2011...
  • Page 67 Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device. Changes or modifications not expressly approved by Adam Equipment could void the user's authority to operate the equipment. WEEE COMPLIANCE...
  • Page 68 For a complete listing of all Adam products visit our website at www.adamequipment.com © Copyright by Adam Equipment Co. Ltd. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment.

Table of Contents