Screw Sizes And Tightening Torques - YASKAWA GA50C4009AJA Installation Manual

Ac drive
Table of Contents

Advertisement

5 Conditions
Table 5.13 Three-Phase 400 V Class (Finless-Type Drive)
Rated Output
Drive Model
4001
4002
4004
4005
4007
4009
4012
4018
4023
4031
4038

Screw Sizes and Tightening Torques

Table 5.14
shows the correct screw sizes and tightening torques to safety the drive to a
metal surface (enclosure panel).
Drive Model
B001 - B012
2001 - 2021
2030 - 2056
2070
18
Carrier
Current
Frequency
(A)
(kHz)
1.2
2
2.1
2
4.1
2
5.4
2
7.1
2
8.9
2
11.9
2
17.5
2
23.4
2
31
2
38
2
Table 5.14 Screw Sizes and Tightening Torques
YASKAWA TOEP C710617 0SB YASKAWA AC Drive GA500 Installation Manual
Drive Watt Loss (W)
Interior Unit
Loss
8
13
14
16
20
28
39
58
81
99
141
Screw Size
M5
M5
M5
M6
Heatsink Plate Loss
(P
)
Loss
7
12
24
32
44
58
83
146
204
259
319
Tightening Torque
N∙m (lbf∙in)
2.0 - 2.5
(17.7 - 22.1)
2.0 - 2.5
(17.7 - 22.1)
2.0 - 2.5
(17.7 - 22.1)
4.0 - 5.0
(35.4 - 44.3)
Total
Loss
15
25
38
48
64
86
122
203
286
357
460