2.1.2

Power supply

DL401
J400
SW400
DL405
J500
J501
DL501
DL403
J103
J102
J406
Figure 3: Power supply set up
1. Connect the AC / DC +12 V power supply adapter to J400, the 9 – 18 V power input connector; LED
DL401 light turns blue.
2. Provide a jumper socket on both J404 and J108, the cellular VCC supply jumpers.
3. Turn SW400, the main power switch, to the "ON" position; LED DL400 light turns green and the
cellular module switches on.