Supermicro AS -1015CS-TNR-EU User Manual page 61

A+ server
Table of Contents

Advertisement

UID LED
The UID LED is on pins 7 and 8 of JF1. Connect the front panel UID LED to this header to
indicate when the rear UID switch is turned on. Refer to the table below for pin definitions.
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below
for pin definitions.
Reset Button
The Reset Button connection is located on pins 3 and 4 of JF1. Attach the hardware reset
switch from the computer case to this header to reset the system. Refer to the table below
for pin definitions.
Power Button
The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both
pins will power on/off the system. This button can also be configured to function as a suspend
button (with a setting in the BIOS). To turn off the power in the suspend mode, press the
button for at least 4 seconds. Refer to the table below for pin definitions.
UID LED
Pin Definitions (JF1)
Pin#
Definition
7
UID LED+
8
UID LED-
Power Fail LED
Pin Definitions (JF1)
Pin#
Definition
5
Power Fail LED+
6
Power Fail LED-
Reset Button
Pin Definitions (JF1)
Pin#
Definition
3
Reset Switch
4
Ground
Power Button
Pin Definitions (JF1)
Pin#
Definition
1
Power Switch
2
Ground
61
Chapter 4: Motherboard Connections

Advertisement

Table of Contents
loading

This manual is also suitable for:

As -1015cs-tnr

Table of Contents