Smear freeze motoroil
here
Torque wrench
Wiring interface
Flare nut
When connect the pipe to the unit or b
wrench. As shown in
Fig.21.
When connect, smear both inside and outside of the flare nut with freeze motor oil, screw it by hand
and then tighten it with spanner.
Refer to
Table 4 to check if the wrench had been tightened (too tight would mangle the nut and lead
leakage).
Diameter(Inch)
φ1/4
φ3/8
φ1/2
φ5/8
φ3/4
Examine the connection pipe to see if it had gas leakage,
insulation, as shown in the Fig.21.
Only use median sponge to entwine the wiring interface of the gas pipe and heat preservation
of the gas collection tube.
Thread fasten(x4)
Spanner
Liquid inlet tube
ackout it from the unit, please do use both spanner and torque
Table 4 the tightening torque needed for tightening nut
Surface thickness(mm)
≥0.5
≥0.71
≥1
≥1
≥1
Median sponge (attachment)
(entwine the wiring interface
with seal mat)
Gas collection tube
Fig.3
Fig.21
Tightening torque (N·m)
and then take the treatment of heat
43
Heat preservation
sheath of liquid inlet
tube (attachment) (for
liquid tube)
Heat preservation
sheath of gas collection
tube (attachment)(for
gas tube)
15-30
30-40
45-50
60-65
70-75
sheath