LINCOLN ELECTRIC
14. If about 15 VDC is detected, the welding terminal control circuit is open. Check for damaged leads
for faulty connections at leads 2 and 4. See Wiring Diagram.
15. If the wiring and components are undamaged and functioning properly, the weld control board is
defective and should be replaced.
16. Perform the Case Cover Replacement Procedure.
Figure F.28 – Stop / (auto idle/run) / (high idle/run) switch and weld mode selector switch locations
STOP / (AUTO IDLE/RUN)
/ (HIGH IDLE/RUN) SWITCH
Cross Country™ 300 Service Manual
WELD MODE
SELECTOR
SWITCH
65