LINCOLN ELECTRIC
TEST POINT (+)
TERMINAL 2
TERMINAL 5
TERMINAL 5
TERMINAL 2
TERMINAL 5
TERMINAL 5
TERMINAL 1
TERMINAL 5
TERMINAL 5
Table F. 3 – Weld mode selector switch tests
TEST POINT (–)
TERMINAL 3
TERMINAL 6
TERMINAL 4
TERMINAL 3
TERMINAL 4
TERMINAL 6
TERMINAL 2
TERMINAL 4
TERMINAL 6
Figure F.11 – Weld mode selector switch location
Cross Country™ 300 Service Manual
EXPECTED READING
LESS THAN ONE OHM
(LOW RESISTANCE)
LESS THAN ONE OHM
(LOW RESISTANCE)
AT LEAST 500K OHMS
(HIGH RESISTANCE)
LESS THAN ONE OHM
(LOW RESISTANCE)
LESS THAN ONE OHM
(LOW RESISTANCE)
AT LEAST 500K OHMS
(HIGH RESISTANCE)
LESS THAN ONE OHM
(LOW RESISTANCE)
LESS THAN ONE OHM
(LOW RESISTANCE)
AT LEAST 500K OHMS
(HIGH RESISTANCE)
WELD MODE
SELECTOR
SWITCH
POSITION
STICK
STICK
STICK
TIG
TIG
TIG
CV
CV
CV
42