9. If another type of resistors is used, jumper leads may need to be attached to the resistor. The leads
can then be used to connect the resistor from terminals B1 to B2 and B4 to B5. See Figure F.6. See
Wiring Diagram.
10. Using the volt/ohmmeter, check the voltage across terminals B1 and B2 then B4 and B5. It should
be zero volts in both cases. See Figure F.6. See Wiring Diagram. If not, repeat the discharge
procedure.
11. Perform the Case Cover Replacement Procedure.
Figure F.3 – Field capacitor location
Cross Country™ 300 Service Manual
FIELD CAPACITOR
(LOCATED UNDER PROTECTIVE COVER)
30