Innova 2.0 Series User Manual

Innova 2.0 Series User Manual

9-10-12-15 hp dc inverter 12-15 hp dc inverter elec 2 kw
Table of Contents

Advertisement

Quick Links

User's manual
(Translation of original
EN
instructions)
N400649A - Rev.00 - 02/2024
..2.0
9-10-12-15 HP DC Inverter
12-15 HP DC Inverter ELEC 2
kW

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2.0 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Innova 2.0 Series

  • Page 1 User's manual (Translation of original instructions) N400649A - Rev.00 - 02/2024 ..2.0 9-10-12-15 HP DC Inverter 12-15 HP DC Inverter ELEC 2...
  • Page 2 By following the suggestions contained in this manual, the product you have purchased will operate without problems giving you optimum room temperatures with minimum energy costs. INNOVA S.r.l. Conformity This unit complies with the European directives: •...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Coding                                                                     p. 5 1.1 Coding accessories .
  • Page 4 4.1.3 Keys functions ........p. 13 4.2 Main functions .
  • Page 5: Coding                                                                     P

    CODING CODING The present manual refers to the products: • ..2.0 MINI - 15 HP DC INVERTER • ..2.0 - 10 HP DC INVERTER • ..2.0 - 12 HP DC INVERTER • ..2.0 MAXI - 15 HP DC INVERTER • ..2.0 ELEC 2 KW - 12 HP DC INVERTER •...
  • Page 6: General Information                                                        P

    GENERAL INFORMATION GENERAL INFORMATION 21 About the manual  I nthefigures This manual was written to provide all the explanations for the correct management of the appliance. 1 The numbers indicate the individual components. This instruction manual forms an integral part of the A The capital letters indicate component assemblies.
  • Page 7: Disposal

    GENERAL INFORMATION It addresses all recipients. Maintenance and Troubleshooting It contains section by control mode and information on the It addresses all recipients. use of the main functions. It contains specific warnings and useful information for regular maintenance work. 22 Disposal waste, but must be taken to the appropriate collection point for the recycling of electrical and electronic equip- ment.
  • Page 8: Unit With Touchpad And Remote Control                                      P

    UNIT WITH TOUCHPAD AND REMOTE CONTROL UNIT WITH TOUCHPAD AND REMOTE CONTROL The touchpad control is supplied as standard in- If the unit with touchpad and remote control is com- stalled on the unit. bined with an M7 series wall control (Cod. EEB749II) the change of functions is only possible via the wall con- trol.
  • Page 9: Main Functions

    UNIT WITH TOUCHPAD AND REMOTE CONTROL 313 Remote control Keys and functions related. Up key Down key This can be used to switch the unit on or off Enables the Automatic function Allows you to activate the Ventilation function Enables the Night function Allows you to activate the Moving Deflector Control function This can be used to select the operating mode (Cooling or Heating) Allows you to activate the Dehumidification function...
  • Page 10: Automatic Function

    UNIT WITH TOUCHPAD AND REMOTE CONTROL Setting temperatures too low or too high is detrimental In this mode the fan is set to minimum speed. to health and an unnecessary waste of energy. The set temperature is automatically changed: • in Heating mode, decreases by - 1 °C after one hour 325 Automatic Function and by another - 1 °C after two hours •...
  • Page 11 UNIT WITH TOUCHPAD AND REMOTE CONTROL 33 Basic menu To access the basic menu ur: Not used press for 10 seconds – uP: Not used Appears 332 Scale To move within the menu or change values – To change the temperature unit of measure To select a menu item and to confirm the changes select –...
  • Page 12 UNIT WITH TOUCHPAD AND REMOTE CONTROL Alarm codes Er01 Room temperature probe disconnect- – ed or faulty Er02 Temperature error of the internal heat – exchanger Er03 Source fluid temperature sensor error – Er04 Source exchanger temperature sensor – error Er05 Indoor fan speed out of range (min/ –...
  • Page 13: Night Function

    M7 SERIES CoNTRol EEB749 M7 SERIES CONTROL EEB749 41 Interface 411 Description They are fitted with: • internal memory with data saving even in case of M7 series LED electronic control panels with touch inter- shut-down or power outage face for wall installation allow: •...
  • Page 14 M7 SERIES CoNTRol EEB749 42 Main functions 421 General start-up In cooling function the symbols is alight with setpoint lower than the room temperature. Before the activation: 427 Set the ventilation speed Minimum Make sure that the remote control is connected to the mains.
  • Page 15: Basic Menu

    M7 SERIES CoNTRol EEB749 43 Basic menu To access the basic menu uP: Not used press and hold for 10 seconds – 432 Scale Appears – release the – To change the temperature unit of measure Appears select – select °C o °F –...
  • Page 16: Maintenance                                                              P

    MAINTENANCE MAINTENANCE 51 Preliminary warnings 511   S pecificwarningsR32 Before each cleaning and maintenance intervention: – disconnect the device from the power mains by turn- ing the system master switch to "OFF" R32 refrigerant gas is slightly flammable and odourless. –...
  • Page 17: Long Period Shut-Down

    MAINTENANCE 53 Long period shut-down For seasonal shutdowns or for long periods: – set the main system switch to off – disable the device The antifreeze function is not on. 54 Suggestions for energy saving • Keep filters clean at all times. •...
  • Page 18: Troubleshooting Table

    TROUBLESHOOTING TROUBLESHOOTING 61 Troubleshooting table In the even of a malfunction, please refer to the following lem is not solved, please contact the authorised technical table. If, after performing the suggested checks, the prob- assistance. Anomalies Possible causes Remedies Check there is power supply (by turning a light on, for example). Check that the thermal-magnetic circuit breaker used exclusively to protect the ap- No power supply pliance has not been tripped (if it has, reset it).
  • Page 19: Use Of The Appliance

    TROUBLESHOOTING If after performing the procedure, the OF alarm re- mains, you should contact the Technical Service Center. 64 Use of the appliance Objects or structural obstacles (furniture, curtains, plants, leaves, blinds, etc.) must not obstruct the nor- mal air flow both from the internal and from the exter- nal grids.
  • Page 20: Technical Information                                                     P

    TECHNICAL INFORMATION TECHNICAL INFORMATION 71 RED Compliance Statement Compliance with 2014/53/EU Radio Equipment Direc- bands used and the maximum RF transmit power of the tive (RED). product for sale in the EU: In accordance with Article 10.8(a) and 10.8(b) of the RED, the following table provides information on the frequency Frequency range (MHz) Max.
  • Page 21 NOTE...
  • Page 22 NOTE...
  • Page 23 NOTE...