Innova 2.0 RINNOVA DUCT Installation, Use And Maintenance Manual

Innova 2.0 RINNOVA DUCT Installation, Use And Maintenance Manual

Built-in horizontal version

Advertisement

Quick Links

INSTALLATION, USE AND MAINTENANCE MANUAL
2.0 RINNOVA DUCT
- Built-in horizontal version -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2.0 RINNOVA DUCT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Innova 2.0 RINNOVA DUCT

  • Page 1 INSTALLATION, USE AND MAINTENANCE MANUAL 2.0 RINNOVA DUCT - Built-in horizontal version -...
  • Page 2: Table Of Contents

    REMOTE PANEL CONNECTION .............................. 15 COMMISSIONING AND METHOD OF USE ............................16 OPERATION OF THE CONTROL PANEL ON THE MACHINE, WIFI AND REMOTE CONTROL ............ 16 TURNING THE UNIT ON AND OFF ............................16 Innova Srl Page 2 Manual 2.0 RINNOVA DUCT...
  • Page 3 ALARMS ......................................22 GENERALITY ................................... 22 PROBLEMS WITHOUT ERROR INDICATION ON THE DISPLAY ....................22 TABLE OF ALARMS SIGNALED BY DISPLAY ..........................23 NOTES AND INFORMATION MAINTENANCE ........................... 24 NOTE ........................................24 Innova Srl Page 3 Manual 2.0 RINNOVA DUCT...
  • Page 4: Generality

    Do not put R410A into the atmosphere: R410A is a fluorinated greenhouse gas, referred to in the Kyoto protocol, with a global warming potential (GWP) = 1975. 1.3 SYMBOLOGY The symbols shown in the following booklet allow you to quickly provide information necessary for the correct use of the unit. Safety symbols Innova Srl Page 4 Manual 2.0 RINNOVA DUCT...
  • Page 5: Warnings

    Make sure that the earth connection is made; do not ground the appliance on distribution pipes. Momentary surges of high intensity could damage the unit Installations performed outside the warnings in this manual or use outside the operating limits will instantly void the warranty. Innova Srl Page 5 Manual 2.0 RINNOVA DUCT...
  • Page 6: Compliance

    There are 2 ePM1 filters on the extracted and injected air; The filter on the supply air is placed after the coil to completely filter any impurities of the input air. On the outside air there is a Coarse pre-filter that protects the cleanliness of the unit; Innova Srl Page 6 Manual 2.0 RINNOVA DUCT...
  • Page 7: Main Components Of The Unit

    Remote panel to be purchased optionally with WIFI or MODBUS RTU for connection up to 10m from the unit for the recessed versions; 1.8 MAIN COMPONENTS OF THE UNIT Innova Srl Page 7 Manual 2.0 RINNOVA DUCT...
  • Page 8: Packaging And Transport

    1.11 DISASSEMBLY AND DISPOSAL Do not disassemble or dispose of the product yourself. Disassembly, demolition, disposal of the product must be carried out by authorized personnel in compliance with local regulations. Innova Srl Page 8 Manual 2.0 RINNOVA DUCT...
  • Page 9: Installation

    Ensure sufficient space for carrying out maintenance activities: the opening of the unit cover (from below) must be guaranteed. Ceiling mount Innova Srl Page 9 Manual 2.0 RINNOVA DUCT...
  • Page 10: Condensate Drain Connection

     make sure that the siphon is always full of water.  The H dimension as per the attached image must be at least H = 50mm; Condensate drain connection Innova Srl Page 10 Manual 2.0 RINNOVA DUCT...
  • Page 11: Areaulic Connections

    The unit provides for operation with constant flow fans that follow the preset flow rates for each speed value; Too long or badly made ducts lead to noise and malfunctions of the unit; Check the maximum useful pressure of the unit; Air flow configurations 2.0 RINNOVA DUCT VIEW FROM TOP Innova Srl Page 11 Manual 2.0 RINNOVA DUCT...
  • Page 12: Assembly Of External Grids

    Keep in mind that the grilles open when the outside air flow is activated to allow the cooling or heating function. For their testing it is therefore essential to operate the air conditioner to cool or heat Mounting external grids Innova Srl Page 12 Manual 2.0 RINNOVA DUCT...
  • Page 13: Electrical Connections

    Furthermore, in the lower part, the electrical panel can be reached with a dedicated door Condensate drain connection Innova Srl Page 13 Manual 2.0 RINNOVA DUCT...
  • Page 14: Electrical Diagram

    CP- REMOTE ON OFF Provides an external connection to enable the unit as a presence or window contact; Comes with a deck supplied; Connections Innova Srl Page 14 Manual 2.0 RENEW DUCT...
  • Page 15: Remote Panel Connection

    The connections for the modbus are indicated with A (+) and B (-) Then consult the modbus manual for the available variables and communication parameters; Panel with WIFI card Panel with modbus card Innova Srl Page 15 Manual 2.0 RENEW DUCT...
  • Page 16: Commissioning And Method Of Use

    The button in question is used to switch the appliance on and off for short periods. If the appliance is stopped for a long time, it must be deactivated by disconnecting the main switch, or removing the plug from the socket Unit ON / OFF Innova Srl Page 16 Manual 2.0 RENEW DUCT...
  • Page 17: Modify Temperature Set

    -When this function is activated, the compressor is never activated and the appliance has no action on either temperature or humidity of the air in the room. It is possible to choose the fan speed Season Change Innova Srl Page 17 Manual 2.0 RENEW DUCT...
  • Page 18: Night Wellness Function

    For each speed, if the air quality is not optimal, the fans increase the flow rates to have greater air exchange and improve the quality of the internal air; Innova Srl Page 18 Manual 2.0 RENEW DUCT...
  • Page 19: Description Of The Uvc Lamp Operation

    -The unit provides for the operation of a UVC lamp with germicidal action placed in the section where the new air enters; The lamp is activated permanently together with the activation of the fans; Innova Srl Page 19 Manual 2.0 RENEW DUCT...
  • Page 20: Maintenance

    If the conditions of the filters allow it, they can be cleaned using a vacuum cleaner or a low pressure compressor. close the filter cover making sure that all screws are tightened; View for filter extraction Innova Srl Page 20 Manual 2.0 RENEW DUCT...
  • Page 21: Lamp Maintenance

    Reposition the lamp, making sure it is well coupled with the relevant lamp holder; Reposition the air inlet filter and screw the bottom cover back on with the appropriate screws; View for lamp maintenance Innova Srl Page 21 Manual 2.0 RENEW DUCT...
  • Page 22: Alarms

    Noise coming from the ducts Check for cracks in the intake / inlet / exhaust pipes Vibrations Panels that vibrate Check the integrity of the aluminum panels and profiles of the unit Innova Srl Page 22 Manual 2.0 RENEW DUCT...
  • Page 23: Table Of Alarms Signaled By Display

    It is not possible to activate any operation of the appliance. failure CP presence contact open The device is activated only if the contact is closed. Check the connection of the terminals. Innova Srl Page 23 Manual 2.0 RENEW DUCT...
  • Page 24: Notes And Information Maintenance

    ___________________________________________________________________________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________________________________________ __________________________________ ________________________________________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________________________________________________________________________________________________________________________ ___________________________________________________________________________________________________________________________________________________________________________________________________ ___________________________________________________________________________________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________________________________________________________________________________ 05 20 20 re v.3 Technical Assistance Center The data contained in this manual can be changed by the manufacturer without prior notice. Innova Srl Page 24 Manual 2.0 RENEW DUCT...