Innova ECA644 User Manual
Hide thumbs Also See for ECA644:

Advertisement

User manual
EN
something new in the air
something new in the air
D C I n v e r t e r
ECA644 - ESD645 - ECA649 - ECA647 - ESD648
E4T643
B4V642 - B10642 - BM1151- BM0152

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECA644 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Innova ECA644

  • Page 1 User manual something new in the air something new in the air D C I n v e r t e r ECA644 - ESD645 - ECA649 - ECA647 - ESD648 E4T643 B4V642 - B10642 - BM1151- BM0152...
  • Page 3 By following the suggestions contained in this manual, the product that you have purchased will operate without problems giving you optimum room temperatures with minimum energy costs. Innova S.r.l Compliance This unit complies with the following European Directives: •...
  • Page 4: Table Of Contents

    ECA644 - ECA647 E4T643 SMART TOUCH Electronic control panel General start-up with continuous on-board modulation Activation Display Heating/cooling operating mode set-up Keys function Stand by General start-up Temperature selection Activation Ventilation speed adjustment Heating/cooling operating mode set-up 4.10 Key locking Stand by 4.11...
  • Page 5: Eca644 - Eca647

    ECA644 - ECA647 ECA644 - ECA647 SMART TOUCH electronic panel with continuous on- board modulation This control makes the room temperature adjustment After 20 seconds from the last action the panel brightness completely autonomous (with adjustable offset will be reduced to increase the comfort during night use keyboard) through AUTO, SILENT, NIGHT and MAX and on the display will appear the room temperature.
  • Page 6: General Start-Up

    ECA644 - ECA647 General start-up In order to control the device from the control panel, it first - Start the system by toggling the main switch has to be connected to mains. If the power line is provided with a main switch, it should be on.
  • Page 7: Automatic Operation

    ECA644 - ECA647 Automatic operation Operation Display Hold the AUTO key. The function activation will be signalled by the relative symbol on the display The ventilation speed will be adjusted automatically setpoint using a PI algorithm. between a minimum and a maximum value, based on the actual distance between the room temperature and the 1.10...
  • Page 8: Deactivation

    ECA644 - ECA647 Deactivation 1.15 Operation Display Press the ON stand-by for about 2 s: When the device is in "stand-by" status (no function) there are no light signals on the display. The control ensures anti-freeze safety even when set to stand-by.
  • Page 9: Eca649

    ECA649 ECA649 SMART TOUCH wall-mounted electronic control panel with room probe The remote wall-mounted ECA649 is an electronic Thanks to the temperature probe it ensures anti-freeze thermostat fitted with temperature probe with safety even when set to stand-by. possibility of controlling one or more (up to a maximum of 30) cooler-convector/cooler-radiators in broadcast (with After 20 seconds from the last action the panel simultaneous data transmission) equipped with electronic...
  • Page 10: General Start-Up

    ECA649 General start-up In order to control the device from the control panel, it first - Start the system by toggling the main switch has to be connected to mains. If the power line is provided with a main switch, it should be on. Activation To activate the device Operation...
  • Page 11: Automatic Operation

    ECA649 Automatic operation Operation Display Hold the AUTO key. The function activation will be signalled by the relative symbol on the display The ventilation speed will be adjusted automatically setpoint using a PI algorithm. between a minimum and a maximum value, based on the actual distance between the room temperature and the Silent operation 2.10...
  • Page 12: Deactivation

    ECA649 2.15 Deactivation Operation Display Press the ON stand-by for about 2 s: When the device is in "stand-by" status (no function) there are no light signals on the display. The control ensures anti-freeze safety even when set to stand-by. 2.16 Room temperature probe offset adjustment In some cases the detected values might not represent...
  • Page 13: Esd645 - Esd648

    ESD645 - ESD648 ESD645 - ESD648 Electronic board with continuous modulation for remote thermostat connection The electronic board for remote control allows the control The main operating parameters, the setpoint and the of all cooler-radiator functions from the wall-mounted room temperature are transmitted from the wall-mounted ECA649 control panel.
  • Page 14: E4T643

    E4T643 E4T643 SMART TOUCH electronic control panel with modulation at fixed speed This control makes the room temperature adjustment Dopo un periodo di 20 secondi dall’ultima azione la completely autonomous (with adjustable offset luminosità del pannello viene appositamente ridotta keyboard) through four speeds by means of a probe per aumentare il confort nelle ore notturne e sul located in the lower side of the device ensuring anti-freeze display viene visualizzata la temperatura ambiente.
  • Page 15: General Start-Up

    E4T643 General start-up In order to control the device from the control panel, it first be on. has to be connected to mains. - Start the system by toggling the main switch If the power line is provided with a main switch, it should Activation To activate the device Operation...
  • Page 16: Ventilation Speed Adjustment

    E4T643 Ventilation speed adjustment Operation Display Use the 4 keys to select the fan speed (automatic, minimum, super silent and maximum). The function activation will be signalled by the relative symbol on the display In automatic mode, when the room temperature is about to thermal and acoustic comfort.
  • Page 17: Room Temperature Probe Offset Adjustment

    E4T643 Room temperature probe offset adjustment 4.13 In some cases the detected values might not represent deviations from the actual room temperature using a the real temperature due to the fact that the temperature reliable tool! probe is located in the lower section of the device. Use this function to adjust the measured value shown on the display within a range of +/- 10 °C in 1°C steps.
  • Page 18: Maintenance

    MAINTENANCE MAINTENANCE External cleaning Disconnect the unit from the power supply before Do not use abrasive sponges or abrasive or corrosive each cleaning and maintenance intervention by setting detergents as you might damage the painted surfaces. the main power supply switch to off. Clean the external surfaces of the cooler-radiator using a Wait for the components to cool down in order to soft cloth dampened with water.
  • Page 19 MAINTENANCE Filter cells removal for mobile suction panel versions Put your hands under the ends of the mobile panel Lift and remove the mobile panel Press the plastic tabs Remove the filter. Mobile panel Filter Plastic tabs Filter removal Filter media cleaning suction the dust from the filter using a vacuum cleaner It is forbidden to use the device without its mesh filter.
  • Page 20: Suggestions For Power Saving

    MAINTENANCE End of the cleaning operations For the grill with flaps versions insert the two tabs in the appropriate slots, turn them and hook them giving them a slight hit on the top. Tabs Slots For mobile panel versions lean it in its position parallel to the front and press until locking it.
  • Page 21: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING Troubleshooting The ventilation does not start even if the water circuit is In case of water leaks or abnormal operation, disconnect filled with hot or cold water. the device from power supply immediately and close the The device is losing water in heating mode. water taps.
  • Page 22 NOTE...
  • Page 23 NOTE...
  • Page 24 INNOVA s.r. l . INNOVA s.r. l . Fraz . St rada, 16 - 38085 PIEVE DI BONO (TN) - ITALY Fraz . Strada, 16 - 38085 PIEVE DI BONO (TN) - ITALY tel.

Table of Contents