Innova Filomuro SLW 400 Installation And User Manual

Innova Filomuro SLW 400 Installation And User Manual

Dc inverter
Hide thumbs Also See for Filomuro SLW 400:
Table of Contents

Advertisement

Installation and user manual
EN
something new in the air
something new in the air
SLW

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Filomuro SLW 400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Innova Filomuro SLW 400

  • Page 1 Installation and user manual something new in the air something new in the air...
  • Page 2: Symbols

    By following the suggestions contained in this manual, the product that you have purchased will operate without problems giving you optimum room temperatures with minimum energy costs. Innova S.r.l Compliance This unit complies with the following European Directives: •...
  • Page 3: Table Of Contents

    Table of contents 1.1Table of contents Symbols GENERAL General warnings Essential safety rules Product range Rated technical specifications Filomuro overall dimensions Dimensions and weight during transportation Dimensions and weight during transportation INSTALLATION Unit placement Installation procedure Installation clearances Opening of aesthetic parts for installation of equipment and connections High wall mount or flush with floor Installation template (measured) Hydraulic connections...
  • Page 4 Temperature selection Automatic operation Silent operation Night function Operation at maximum ventilation speed Key locking Minimum brightness reduction Deactivation Room temperature probe offset adjustment Long term shut-down Error signals Electronic board with continuous modulation for remote thermostat connection LED Signals (ref. A) ROUTINE MAINTENANCE Maintenance External cleaning...
  • Page 5: General En

    GENERAL General warnings system otherwise. After unpacking, make sure that all the components are present. If not, contact your vendor who sold the device A temperature that is too low or too high is harmful to to you. health and is an unnecessary waste of energy. Avoid direct contact with the air flow over an extended Only qualified...
  • Page 6: Product Range

    GENERAL It is forbidden to climb with your feet on the device and/ or to place any kind of object on top of it. The external components of the device can reach temperatures of more than 70 °C. Product range The cooler-radiators of the Filomuro range are available in The terminal is available in three different performance levels the SLW version for high wall mount installation or flush with...
  • Page 7: Filomuro Overall Dimensions

    GENERAL Filomuro overall dimensions 2 pipes U.M. SLW 400 SLW 600 SLW 800 Dimensions 1,102 1,302 Dimensions and weight during transportation Dimensions and weight during transportation Packaging M.E. SLW 400 SLW 600 SLW 800 Dimensions Weight 1,035 1,235 1,435...
  • Page 8: Installation

    INSTALLATION INSTALLATION Unit placement - the wall surface is not crossed by pipelines or power lines; Avoid installing the unit near: - the wall is perfectly level; areas exposed to direct sunlight; - there are no obstructions nearby that could compromise the heat sources;...
  • Page 9: Opening Of Aesthetic Parts For Installation Of Equipment And Connections

    INSTALLATION Opening of aesthetic parts for installation of equipment and connections Remove the side panels by unthreading them upwards - Remove the aesthetic front panel as shown in the figure; as shown in the figure below; Remove the 6 hex screws present on the sides of the front panel;...
  • Page 10 INSTALLATION Remove the upper grille by unthreading it in your direction - remove the side panels by lifting them upwards; and lifting it upwards, as shown in the figure; upper grille side panels...
  • Page 11: High Wall Mount Or Flush With Floor

    INSTALLATION High wall mount or flush with floor • For smooth installation, especially if you want to set-up • another option if you can comfortably bend the pipeline the system before you install the device, we recommend (which will depend on the depth of the installed cistern) installing a built-in cistern, as shown in the figure;...
  • Page 12 INSTALLATION Use the paper template shown in full scale on the next Firmly fasten the brackets by tightening the four screws. page and trace the position of the two fixing brackets on Check stability by moving the brackets to the right and the wall.
  • Page 13 INSTALLATION...
  • Page 14: Installation Template (Measured)

    INSTALLATION Installation template (measured)
  • Page 15 INSTALLATION...
  • Page 16: Hydraulic Connections

    INSTALLATION Hydraulic connections U.M. Pipeline diameter The engineer is responsible for choosing the right water lines The hydraulic lines and fittings must be thermally insulated. and their size, in accordance with good installation practices Avoid partial insulation of the pipes. and the applicable laws, keeping in mind that under-sized pipelines lead to poor system operation.
  • Page 17 INSTALLATION Connection of the fain coil flush with the wall with a 2-way valve and thermoelectric command (V20687) Connect the pipeline to the delivery and return lines as shown Comply with the requirements for electrical connections, as in the figure, with the delivery line at the top; described in para.
  • Page 18: Condensate Drain

    INSTALLATION Condensate drain The condensate drain network must be sized appropriately flow, remember to install a pump: (minimum inner pipe diameter: 14 mm) and the pipeline positioned so that it maintains a consistent slope along the These pumps are commonly available on the market. line (never less than 1%).
  • Page 19: Filling The Plant

    INSTALLATION Pay attention to the tilt of the condensate drain pipe when it channels condensate outside the premises as shown in the figure. fan coil condensate drain pipe Filling the plant When starting system, make sure that is already running, use its cap to press the valve shutter and lock-shield hydraulic unit...
  • Page 20: 2.11 Wiring

    INSTALLATION 2.11 Wiring • Access the electrical parts as described in para. 2.4. view. • An on/off switch with delayed fuses or an automatic • The power cables must be equipped with copper circuit breaker (2A) must be installed to supply power to conductors having the following unitary sections (the the system.
  • Page 21: Control Panel Installation And Connection

    INSTALLATION CONTROL PANEL INSTALLATION AND CONNECTION 3.1 ER0689 board connections in the upper part of the wall). Before you connect the cooler-radiator, make sure that: In any case, you must check that the power supply is the voltage and frequency match the values on the protected against overload and/or short-circuits.
  • Page 22: Er0690 Connections

    INSTALLATION ER0690 connections serial connection for wall-mounted remote Connect as an alternative to the air probe of the -AB+ control ECA649 (respect the AB polarisation) ECA649 wall-mounted control panel H2** hot water temperature probe 10 kΩ If after powering the equipment the board fan motor DC inverter detects the probe, the start-up will take place under normal conditions with minimum water...
  • Page 23: Fitting The Wall-Mounted Remote Control Panel Eca649

    INSTALLATION Fitting the wall-mounted remote control panel ECA649 The wall-mounted ECA649 is an electronic thermostat (fitted on their back (A). with temperature probe optionally remotable in one of the Use the base of the control (ref. B in figure) to trace the fixing fancoils connected to it) with the possibility of controlling one point on the wall (use the two opposite holes).
  • Page 24: Spring Clamps -Ab+ And Cp Connection

    INSTALLATION 3.3.1 Spring clamps -AB+ and CP connection The spring terminals intended for the electrical connections insert the cables completely and make sure they are properly are compatible with 0.2 to 1.5 mm² section rigid or flexible fixed by pulling them slightly; cables, while if they are provided with lugs with plastic collar, To disconnect the cables use a screwdriver to press the their maximum section is reduced to 0.75 mm².
  • Page 25: Eca649 Connections

    INSTALLATION ECA649 connections 3.3.3 Connect the RS485 line of the wall-mounted remote control the indications “A” and “B” on each peripheral device to one or more (up to a maximum of 30) units equipped with connected (for the connection it is preferable to use a electronic remote control ER0690 through a bipolar cable bipolar shielded cable with a minimum section of 0.35 suitable for RS485 serial connection, keeping it separate from...
  • Page 26: Diagram For Bb0698 Connections With 3-Speed Thermostats

    INSTALLATION Diagram for BB0698 connections with 3-speed thermostats Make the electrical connections to a thermostat that is suitable for the purpose, according to the diagram in the picture 230V-50Hz electric power supply 3 speed thermostat (to buy, install and connect by the installer) electrovalve consent input maximum fan speed...
  • Page 27: Bb0698 Connection With 3-Speed Thermostats

    INSTALLATION BB0698 connection with 3-speed thermostats 3.4.1 The CV input is the ON/OFF of the board, which goes into for example connect the medium V2, minimum V3 and stand-by with the input open. It must be bridged to clamp L supersilent V4 speeds for residential application that requires of the 230V electric power supply to activate the electrovalve maximum silence, or connect V1, V2 and V3 for commercial...
  • Page 28: Water Probe Management With 3-Speed Thermostat

    INSTALLATION 3.4.3 Water probe management with 3-speed thermostat If the BB0698 board is used with electromechanical thermostats, or WIN input (ref. C) of the board: by leaving the input open, the board other commercial commands, provided with water probe, the on- goes into heating mode;...
  • Page 29: Diagram For Bb0699 Connections With 0-10 V Dc Thermostats/Signals

    INSTALLATION Diagram for BB0699 connections with 0-10 V DC thermostats/signals Make the electrical connections to a thermostat that is suitable for the purpose, according to the diagram in the picture 230V-50 Hz electric power supply Step motor (diffuser) device pilot input 0÷10 V water solenoid valve...
  • Page 30: Bb0698 Board + Thermostat Bm1151 Wiring Diagram

    INSTALLATION BB0698 board + thermostat BM1151 Wiring diagram The wall-mounted control BM1151 is an electronic thermostat for powering an electrovalve and a presence sensor input (if with ON/OFF switch, a three-speed switch and a summer/ closed, the fan coil goes into stand-by). winter switch.
  • Page 31: Bb0698 Board + Timer Bm0152 Wiring Diagram

    INSTALLATION BB0698 board + timer BM0152 Wiring diagram The built-in control kit BM0152 allows to adjust all the functions during the heating mode (30 °C) and maximum functions of the fan coil. It is equipped with a live output functions during the cooling mode (20 °C) with a hysteresis for powering an electrovalve.
  • Page 32: Operating Instructions With Remote Control (For Command 0689)

    INSTRUCTION MANUAL OPERATING INSTRUCTIONS WITH REMOTE CONTROL (for command 0689) Warnings The device must not be installed in rooms where there are Do not lean or sit on the body of the cooler-radiator to avoid explosive gases or where there are conditions of humidity damaging it.
  • Page 33: Functional Description

    INSTRUCTION MANUAL You can set the various functions by pressing the keys (see device while you are using the remote. the keys function chapter). Moreover: The remote control supplied with the device is designed to if other devices are being used within the premises that provide maximum sturdiness and exceptional functionality, are operated by remote control (TVs, radios, stereos, but should nonetheless be handled with caution.
  • Page 34: Airflow Direction Control

    INSTRUCTION MANUAL Key/Display Operation Power on/off By pressing the appropriate key, you can switch the device off (standby) or on. The control panel has its own memory, therefore no settings will be lost in case of shut-down or power outage. The key is used to activate or deactivate the unit for short periods.
  • Page 35 INSTRUCTION MANUAL Key/Display Operation Setting the Timer function • The device’s operating logic allows the user to freely programme when it is to switch on or off. • While the cooler-radiator is on, you can programme it to switch off by pressing the Timer key and then setting the number of hours (from 1 to 24) after which the device is to switch to stand-by.
  • Page 36: Troubleshooting

    INSTRUCTION MANUAL Operating the unit if the remote control is not available If you lose the remote control, the batteries run out or the remote stops working, you can be operate the device with the keys on the touch- screen display on-board the machine. Troubleshooting For the user it is important to distinguish any malfunction or contact the Technical Customer Service.
  • Page 37: Instructions For Use With Wall-Mounted Control Panel

    INSTRUCTION MANUAL INSTRUCTIONS FOR USE WITH WALL-MOUNTED CONTROL PANEL SMART TOUCH wall-mounted electronic control panel with room probe The wall-mounted control panel ECA649 is a thermostat fitted safety even when set to stand-by. with temperature probe with the possibility of controlling one or more (up to a maximum of 30) cooler-convector/cooler- After 20 seconds from the last action the panel brightness radiators in broadcast (with simultaneous data transmission)
  • Page 38: General Start-Up

    INSTRUCTION MANUAL General start-up In order to control the device from the control panel, it first it must be activated. has to be connected to mains. - Start the system by toggling the main switch If a main power switch has been installed on the power line, Activation To activate the device Operation...
  • Page 39: Automatic Operation

    INSTRUCTION MANUAL Automatic operation Operation Display Hold the AUTO key. The function activation will be signalled by the relative symbol on the display The ventilation speed will be adjusted automatically between point based on an algorithm type PI. a minimum and a maximum value, based on the actual distance between the room temperature and the pre-set set- Silent operation 5.10...
  • Page 40: Deactivation

    INSTRUCTION MANUAL 5.15 Deactivation Operation Display Press the ON stand-by for about 2 s: When the device is in "stand-by" status (no function) there are no light signals on the display. The control ensures anti-freeze safety even when set to stand-by.
  • Page 41: 5.19 Electronic Board With Continuous Modulation For Remote Thermostat Connection

    INSTRUCTION MANUAL 5.19 Electronic board with continuous modulation for remote thermostat connection The electronic board for remote control allows the control of control panel ECA649 to all connected terminals in the all cooler-radiator functions from the wall-mounted ECA649 network, ensuring smooth operation. control panel.
  • Page 42: Routine Maintenance

    INSTRUCTION MANUAL ROUTINE MAINTENANCE Maintenance Routine maintenance is essential to keep the cooler- (for other tasks) by our Technical Customer Service, filomuro always efficient, safe and reliable radiator which is qualified for such tasks and which can also over time. Routine maintenance performed...
  • Page 43: Cleaning The Air Suction Filter

    INSTRUCTION MANUAL Cleaning the air suction filter After prolonged operation and so as to factor the concentration after prolonged disuse, proceed as follows. of impurities in the air, or when you plan to restart the system Extraction of filter cells Remove the filter cells by lifting them slightly and turning Remove the filter by pulling it horizontally and upwards.
  • Page 44: Suggestions For Power Saving

    INSTRUCTION MANUAL Filter media cleaning suction the dust from the filter using a vacuum cleaner It is forbidden to use the device without its mesh filter. wash the filter with running water without using any detergents or solvents and then let it dry. The device features a safety switch hat prevents the fan Remount the filter on the cooler-radiator, paying particular from starting if the mobile panel is incorrectly positioned...
  • Page 45: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING The ventilation does not start even if the water circuit is filled In case of water leaks or abnormal operation, disconnect with hot or cold water. the device from power supply immediately and close the The device is losing water in heating mode. water taps.
  • Page 46 NOTES...
  • Page 47 NOTES...
  • Page 48 INNOVA s.r. l . INNOVA s.r. l . Fraz . Strada, 16 - 38085 PIEVE DI BONO (TN) - ITALY Fraz . Strada, 16 - 38085 PIEVE DI BONO (TN) - ITALY tel.

This manual is also suitable for:

Filomuro slw 600Filomuro slw 800

Table of Contents